      <Title language="en">Cleaning and disinfection of surfaces in hospitals. Improvement in quality of structure, process and outcome in the hospitals in Frankfurt&#47;Main, Germany, in 2016 compared to 2014</Title>
      <TitleTranslated language="de">Fl&#228;chenreinigung und -desinfektion in Krankenh&#228;usern. Verbesserung der Struktur-, Prozess- und Ergebnisqualit&#228;t in den Krankenh&#228;usern in Frankfurt am Main, 2016 im Vergleich zu 2014</TitleTranslated>
    </TitleGroup>
    <CreatorList>
      <Creator>
        <PersonNames>
          <Lastname>Hausemann</Lastname>
          <LastnameHeading>Hausemann</LastnameHeading>
          <Firstname>Angelika</Firstname>
          <Initials>A</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Public Health Department of the City of Frankfurt&#47;Main, Germany</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Gr&#252;newald</Lastname>
          <LastnameHeading>Gr&#252;newald</LastnameHeading>
          <Firstname>Miriam</Firstname>
          <Initials>M</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Public Health Department of the City of Frankfurt&#47;Main, Germany</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Otto</Lastname>
          <LastnameHeading>Otto</LastnameHeading>
          <Firstname>Ulla</Firstname>
          <Initials>U</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Public Health Department of the City of Frankfurt&#47;Main, Germany</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Heudorf</Lastname>
          <LastnameHeading>Heudorf</LastnameHeading>
          <Firstname>Ursel</Firstname>
          <Initials>U</Initials>
          <AcademicTitle>Prof. Dr.</AcademicTitle>
        </PersonNames>
        <Address>Public Health Department of the City of Frankfurt&#47;Main, Breite Gasse 28, 60311 Frankfurt&#47;Main, Germany, Phone: &#43;49 69 212 36980, Fax: &#43;49 69 212 30475<Affiliation>Public Health Department of the City of Frankfurt&#47;Main, Germany</Affiliation></Address>
        <Email>ursel.heudorf&#64;stadt-frankfurt.de</Email>
        <Creatorrole corresponding="yes" presenting="no">author</Creatorrole>
      </Creator>
    </CreatorList>
    <PublisherList>
      <Publisher>
        <Corporation>
          <Corporatename>German Medical Science GMS Publishing House</Corporatename>
        </Corporation>
        <Address>D&#252;sseldorf</Address>
      </Publisher>
    </PublisherList>
    <SubjectGroup>
      <SubjectheadingDDB>610</SubjectheadingDDB>
      <Keyword language="en">hospital hygiene</Keyword>
      <Keyword language="en">surface cleaning</Keyword>
      <Keyword language="en">surface disinfection</Keyword>
      <Keyword language="en">infection control visits</Keyword>
      <Keyword language="en">public health department</Keyword>
      <Keyword language="de">Krankenhaushygiene</Keyword>
      <Keyword language="de">Fl&#228;chenreinigung</Keyword>
      <Keyword language="de">Fl&#228;chendesinfektion</Keyword>
      <Keyword language="de">Hygienekontrollen</Keyword>
      <Keyword language="de">&#246;ffentlicher Gesundheitsdienst</Keyword>
    </SubjectGroup>
    <DatePublishedList>
      
    <DatePublished>20180717</DatePublished></DatePublishedList>
    <Language>engl</Language>
    <License license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/4.0/">
      <AltText language="en">This is an Open Access article distributed under the terms of the Creative Commons Attribution 4.0 License.</AltText>
      <AltText language="de">Dieser Artikel ist ein Open-Access-Artikel und steht unter den Lizenzbedingungen der Creative Commons Attribution 4.0 License (Namensnennung).</AltText>
    </License>
    <SourceGroup>
      <Journal>
        <ISSN>2196-5226</ISSN>
        <Volume>13</Volume>
        <JournalTitle>GMS Hygiene and Infection Control</JournalTitle>
        <JournalTitleAbbr>GMS Hyg Infect Control</JournalTitleAbbr>
      </Journal>
    </SourceGroup>
    <ArticleNo>06</ArticleNo>
  </MetaData>
  <OrigData>
    <Abstract language="de" linked="yes"><Pgraph>Neben der H&#228;ndehygiene und der Instrumentenaufbereitung kommt der Fl&#228;chenreinigung und -desinfektion in Kliniken eine wichtige Bedeutung in der Verhinderung von Erreger&#252;bertragungen und damit auch Infektionen zu. Nachdem bei einer umfassenden, standardisierten Erhebung der Struktur-, Prozess- und Ergebnisqualit&#228;t der Fl&#228;chenaufbereitung der Frankfurter Kliniken im Jahr 2014 deutlicher Verbesserungsbedarf gefunden wurde, wurde diese Erhebung im Jahr 2016 mit identischer Methode wiederholt. </Pgraph><Pgraph><Mark1>Methoden:</Mark1> Wie in 2014 wurden auch in 2016 alle Krankenh&#228;user im Hinblick auf die Strukturqualit&#228;t (incl. Vertr&#228;ge mit Reinigungsfirmen, Qualit&#228;tsanforderungen, vereinbarte Zeitkontingente etc.) und die Prozess- und Ergebnisqualit&#228;t &#252;berwacht. Da inzwischen ein Haus geschlossen hat, betraf dies jetzt insgesamt 16 H&#228;user (2014: 17). Vor Ort wurde die Reinigung in jeweils mindestens 5 Zweibettzimmern pro Krankenhaus beobachtet und die Ergebnisqualit&#228;t an jeweils 15 vorab standardisiert angebrachten fluoreszierenden Markierungen (Glow-Check) erhoben. </Pgraph><Pgraph><Mark1>Ergebnisse:</Mark1> Strukturqualit&#228;t &#91;Werte aus 2014&#93;: In 14 (88&#37;) Kliniken hatten die Vorarbeiter die geforderte Qualifikation &#91;2014: 12; 71&#37;&#93;. In 15 (94&#37;) Kliniken gab es Schnittstellenpl&#228;ne, d.h. genaue Angaben f&#252;r den Reinigungs- und Pflegedienst &#91;11; 65&#37;&#93;. Eine &#8222;volle Reinigungsleistung&#8220; an Samstagen wurde in 12 (75&#37;) Kliniken &#91;12; 71&#37;&#93;, an Sonntagen in 4 (25&#37;) Kliniken angegeben &#91;2; 12&#37;&#93;. Die vertraglich vorgegebene Reinigungsleistung (beobachtete Leistung in Klammern) lag im Mittel bei 168 m<Superscript>2</Superscript>&#47;h (155 m<Superscript>2</Superscript>&#47;h) pro Patientenzimmer &#91;178 und 148 m<Superscript>2</Superscript>&#47;h&#93; und bei 63 m<Superscript>2</Superscript>&#47;h (34 m<Superscript>2</Superscript>&#47;h) pro Nasszelle &#91;69 und 33 m<Superscript>2</Superscript>&#47;h&#93;. Bei der Beobachtung der Prozessqualit&#228;t wurden die verschiedenen Handkontaktfl&#228;chen im Jahr 2016 besser aufbereitet. Bei der Pr&#252;fung der Ergebnisqualit&#228;t: wurden 88&#37; der erreichbaren Punkte erreicht &#91;2014: 75&#37;&#93;. </Pgraph><Pgraph><Mark1>Schlussfolgerung:</Mark1> Im Vergleich zu 2014 zeigte sich 2016 eine deutliche Verbesserung, insbesondere in den H&#228;usern bzw. in den Bereichen, bei welchen zuvor ein h&#246;herer Verbesserungsbedarf festgestellt worden war. Die H&#228;user haben teilweise erhebliche Anstrengungen unternommen &#8211; u.a. bei der Schulung des Personals und der Kontrolle der Reinigung. Gleichwohl werden immer wieder teilweise auch erhebliche Fehler beobachtet und es erreichen uns Patientenbeschwerden wegen Reinigungsm&#228;ngeln, d.h. weitere Verbesserungen sind erforderlich.</Pgraph></Abstract>
    <Abstract language="en" linked="yes"><Pgraph>The cleaning and disinfection of surfaces in hospitals is becoming increasingly important in the multi-barrier approach for preventing infection, in addition to hand hygiene and proper reprocessing of medical devices. Therefore, in 2014, the quality of structure, process and outcome of surface preparation was checked in all hospitals in Frankfurt&#47;Main, Germany. Because of great need for improvements, this monitoring was repeated in 2016. The data are presented in comparison to those in 2014.</Pgraph><Pgraph><Mark1>Methods:</Mark1> All 16 hospitals provided information on the quality of structure. Data on quality of process was obtained through direct observation during cleaning and disinfection of rooms and their bathrooms. Data on quality of result was acquired using the fluorescence method, i.e., marking surfaces with a fluorescent liquid and testing whether this mark has been sufficiently removed by cleaning. The results are compared to those of the 17 hospitals monitored in 2014, before the closing of one of the hospitals<Mark1>.</Mark1></Pgraph><Pgraph><Mark1>Results:</Mark1> Quality of structure &#91;data from 2014&#93;: In all hospitals, the employees were trained regularly. In 14 (88&#37;) &#91;12; 71&#37;&#93; of those, the foremen had the required qualifications. In 1 (6&#37;) &#91;6; 35&#37;&#93; hospitals, some uncertainty remained concerning the interface of the cleaning and nursing care services. A complete cleaning was reported to take place in 12 (75&#37;) &#91;12; 70&#37;&#93; hospitals on Saturdays and in 4 (25&#37;) &#91;<TextGroup><PlainText>2; 11&#37;&#93;</PlainText></TextGroup> hospitals on Sundays. Quality of process: During process monitoring, the different surfaces with frequent hand or skin contact were prepared to different extents (91&#8211;100&#37;) &#91;70&#8211;100&#37;&#93;. Quality of result: 88&#37; &#91;75&#37;&#93; of fluorescent marks were appropriately removed. </Pgraph><Pgraph><Mark1>Conclusion:</Mark1> Compared to 2014, a clear improvement were seen in 2016, especially in the qualification of the foremen and in terms of clearly defining the interface between cleaning and care services as well as the quality of process and outcome. Nevertheless, regarding the growing importance of proper reprocessing of hospital surfaces for prevention of infections and&#47;or coloni<TextGroup><PlainText>za</PlainText></TextGroup>tions, further improvements are mandatory, including a program for better education of the cleaning staff.</Pgraph></Abstract>
    <TextBlock linked="yes" name="Introduction">
      <MainHeadline>Introduction</MainHeadline><Pgraph>Good hygiene is crucial for the prevention of infections and pathogen transmission in the hospital. With more older, multimorbid patients and shorter hospital stays, more invasive methods in diagnostics and therapy, and more medical devices, the risk of infections has increased during the past years. </Pgraph><Pgraph>Cleaning and disinfection of surfaces in the hospital is becoming increasingly important in the multi-barrier approach for preventing infection, in addition to hand hygiene and proper reprocessing of medical devices. With new publications available, previous controversial discussions <TextLink reference="1"></TextLink> as to the role of surface disinfection have declined. The relevance of surface disinfection is being increasingly accepted. In their review, Gebel at al. <TextLink reference="2"></TextLink> stated: </Pgraph><Pgraph><UnorderedList><ListItem level="1">&#8220;There is good evidence that contaminated dry surfaces contribute to the spread of nosocomial pathogens.</ListItem><ListItem level="1">It is undisputed that environmental disinfection is necessary in certain risk areas and in outbreak situations.</ListItem><ListItem level="1">It is widely acknowledged that proper use of disinfectants contributes to the control of pathogens in outbreak situation as part of a bundle strategy.&#8221;</ListItem></UnorderedList></Pgraph><Pgraph>In the meantime, several national guidelines and recommendations have become available <TextLink reference="3"></TextLink>, <TextLink reference="4"></TextLink>.</Pgraph><Pgraph>In Germany, the national Hospital Hygiene and Infection Prevention Commission KRINKO emphasizes the multi-barrier approach, defines surfaces and areas with different transfer risks, and attaches particular importance to the regular and appropriate disinfection of the surfaces with frequent hand and skin contact <TextLink reference="3"></TextLink>. The commission emphasizes the importance of proper training and instruction, as well as the supervision of staff, and the need to &#8220;provide sufficient time for the work to be carried out properly&#8221;. However, the commission does not itself provide any defined training requirements or reference values for the surfaces to be cleaned per unit time.</Pgraph><Pgraph>Further support is provided by the German Society for Hospital Hygiene (DGKH) in its &#8220;Hygienic Criteria for the Cleaning Service&#8221; from 2013 <TextLink reference="5"></TextLink>, especially with regard to the selection and commissioning of cleaning service providers. Requirements for the certification of the service providers and basic training of the managers according to the guidelines of GUV-R 107-002 and GUV-R 101-10 have been published <TextLink reference="6"></TextLink>, <TextLink reference="7"></TextLink>. </Pgraph><Pgraph>Regarding time allotted for cleaning and disinfection of defined surfaces (m<Superscript>2</Superscript>&#47;h), current guidelines have been published by the RAL-G&#252;tegemeinschaft Geb&#228;udereinigung e.V. in 2011 <TextLink reference="8"></TextLink>: In the patient rooms in hospitals, 130&#8211;220 m<Superscript>2</Superscript> should be reprocessed per hour, and in toilets, showers and baths 60&#8211;120 m<Superscript>2</Superscript>&#47;h. </Pgraph><Pgraph>Based on these guidelines, the public health department in Frankfurt&#47;Main, Germany, has monitored cleaning and disinfection of surfaces in the hospitals of Frankfurt for many years. In 2014, the systematic monitoring of quality of structure, process, and outcome of surface preparation of all hospitals in Frankfurt&#47;Main exhibited a great need for improvement <TextLink reference="9"></TextLink>. Therefore, in 2016, this monitoring was repeated. The data are presented here in comparison to those in 2014.</Pgraph></TextBlock>
    <TextBlock linked="yes" name="Materials and methods">
      <MainHeadline>Materials and methods</MainHeadline><Pgraph>Based on the recommendations of the KRINKO and of the DGKH <TextLink reference="3"></TextLink>, <TextLink reference="5"></TextLink> the structural, process, and outcome quality of cleaning and disinfection in all Frankfurt hospitals was monitored and compared to the data of 2014. In the interim, one hos<TextGroup><PlainText>pital</PlainText></TextGroup> has closed, so that in 2016, 16 hospitals and in 2014, 17 hospitals were monitored.</Pgraph><SubHeadline>Structural quality</SubHeadline><Pgraph>As part of a questionnaire-based survey, data was obtained regarding the qualification of the foreman, staff training and quality control, the interface of the responsibilities of house cleaning and nursing personnel, the work instructions (standard operating procedures SOP), the cleaning performance on weekends, and time commissioned for the preparation of a two-bed room as well as a bathroom. The reprocessing of the beds was not the subject of the survey.</Pgraph><Pgraph> </Pgraph><SubHeadline>Process quality</SubHeadline><Pgraph>On the day of the control visit, reprocessing of at least 5 two-bed rooms and bathrooms was monitored in every hospital. Reprocessing was surveyed by employees of the Public Health Department and recorded in detail, including the time consumed.</Pgraph><SubHeadline>Outcome quality </SubHeadline><Pgraph>Before the visit, hygiene personnel of the respective hospitals had marked definite points in fluorescent ink, according to the CDC&#8217;s recommendation <TextLink reference="10"></TextLink>. During the control visit, if and how these points had been removed by cleaning was determined using an ultraviolet flashlight. Complete removal of the mark was scored as two points, partial removal was given one point, and zero points were awarded if the mark was still visible, i.e. this area had not been processed.</Pgraph></TextBlock>
    <TextBlock linked="yes" name="Results">
      <MainHeadline>Results</MainHeadline><SubHeadline>Structural quality</SubHeadline><Pgraph>Table 1 <ImgLink imgNo="1" imgType="table"/> shows the data of structural quality. Compared to 2014, more hospitals provided a plan for cleaning and disinfection with detailed definitions of the tasks of the cleaning service (usually all surfaces) and nursing care service (usually surfaces of medical devices). Two more hospitals had trained their foreman properly and had increased the range of cleaning on Sundays, now covering complete cleaning (comparable to normal working days). Most of the hospitals had implemented internal routine control via fluorescent markers.</Pgraph><Pgraph>In Table 2 <ImgLink imgNo="2" imgType="table"/>, the cleaning performance, expressed as m<Superscript>2</Superscript> per hour, recommended by the RAL is depicted and compared to data of the DGKH in 2013 (questionnaire survey) and the on-site surveys in Frankfurt hospitals 2014 and 2016. The commissioned m<Superscript>2</Superscript> per hour for the cleaning of the patient rooms and bathrooms in Frankfurt&#47;Main were within the range indicated in the RAL recommendation. However, the performance for the cleaning of the bathrooms was very much lower than commissioned &#8211; with no significant differences between 2014 and 2016.</Pgraph><SubHeadline>Process quality</SubHeadline><Pgraph>Time commissioned and time required for the reprocessing of surfaces varied widely between the hospitals (Figure 1 <ImgLink imgNo="1" imgType="figure"/>) &#8211; in 2016 as well as in 2014. In the patients&#8217; rooms in most hospitals, the observations corresponded to the commissioned time, but in the bathrooms, performance was much lower than commissioned &#8211; in all hos<TextGroup><PlainText>pitals</PlainText></TextGroup> and in 2016 as well as in 2014.</Pgraph><Pgraph>Figure 2 <ImgLink imgNo="2" imgType="figure"/> shows that in 2016 the processing of door handles, bedframe light switch, etc. was done properly in more than 90&#37; of the rooms. Compared to 2014, improvements could be seen especially at those sites which had previously been reprocessed insufficiently, i.e., the call button, phone, drawer handle of the bed table, and door handle and light switch in the bathroom.</Pgraph><SubHeadline>Outcome quality</SubHeadline><Pgraph>For monitoring the effect of cleaning and disinfection, the glow-check method was used. When scoring complete removal of the mark as two points and partial removal by one point, in total, 87.8&#37; of the maximum number of points possible were reached in 2016. This is a good improvement compared to 2014, when a compliance of 75&#37; was observed. In 2016, compliance in the different hospitals ranged from 67&#8211;100&#37;, compared to 49&#8211;97&#37; in the initial examination in 2014. Especially in the hospitals with bad compliance in 2014, improvements were demanded and achieved (Figure 3 <ImgLink imgNo="3" imgType="figure"/>).</Pgraph><Pgraph>Regarding the various marked sites, the best improvements were seen at those points which had been poorly reprocessed in 2014 (Figure 4 <ImgLink imgNo="4" imgType="figure"/>). Hence, the results of the observation for process quality are confirmed. </Pgraph><Pgraph>In Table 3 <ImgLink imgNo="3" imgType="table"/>, the results of this survey are compared with data from the literature <TextLink reference="9"></TextLink>, <TextLink reference="11"></TextLink>, <TextLink reference="12"></TextLink>, <TextLink reference="13"></TextLink>, <TextLink reference="14"></TextLink>, <TextLink reference="15"></TextLink>, <TextLink reference="16"></TextLink>, <TextLink reference="17"></TextLink>. For comparison reasons, only the full removal of the marks was taken into account. In 2016, 85&#37; of the marks in the Frankfurt hospitals was removed completely, resulting in a 22&#37; improvement compared to the first survey in 2014 &#91;9&#93;. In the other studies published, a maximum of 85&#37; compliance was also found. It is striking that in the other studies, however, improvement rates of up to 57&#37; were found <TextLink reference="11"></TextLink>, <TextLink reference="12"></TextLink>, <TextLink reference="13"></TextLink>, <TextLink reference="14"></TextLink>, <TextLink reference="15"></TextLink>, <TextLink reference="16"></TextLink>, <TextLink reference="17"></TextLink>. In Frankfurt, a 22&#37; increase was observed due to better compliance in the initial examination in 2014 (63&#37; vs 23&#8211;47&#37; in other studies).</Pgraph></TextBlock>
    <TextBlock linked="yes" name="Discussion">
      <MainHeadline>Discussion</MainHeadline><Pgraph>Postal surveys are often carried out on hygiene in hospitals. These can usually record the structural quality only. Good structural quality (i.e., personnel, equipment, training, and control of employees) is a necessary but not sufficient prerequisite for good hygiene. Good structural quality does not automatically guarantee good process quality. In the event of staff shortage, illness, frequent personnel changes, and lack of training and control of the employees, the process quality can be insufficient despite good structural quality. In an earlier study by the Health Office on surface reprocessing in nursing homes, only small and not significant correlations between structural quality on the one hand and process and outcome quality on the other were found <TextLink reference="18"></TextLink>. Therefore, for assessing the quality of hygiene, it is also important to check the process and outcome quality.</Pgraph><Pgraph>This was done in the present survey. Before discussing the results, however, the limitations should be addressed. Regarding process quality, detailed observations of the processes were carried out. Whereas the process quality of automatic procedures can be monitored easily by monitoring the technical data, all manual procedures, such as hand hygiene and surface preparation, including manual steps in medical device preparation, must be observed. Thus, an observer effect cannot to be excluded; on the contrary, such an effect is very probable. Hence, the process quality of surface reprocessing can only be assessed with restrictions. A Hawthorne effect has to be taken into account. The process quality may also be influenced if &#8211; in the case of announced examinations of the public health department &#8211; only selected personnel is provided, or especially carefully prepared.</Pgraph><Pgraph>The examination of the quality of outcome, defined as the prevention of infections, is virtually impossible, since prevented infections cannot be shown statistically, or at best can only be statistically represented by large numbers of cases. Attributing it to individual factors such as hand hygiene, surface cleaning and disinfection or reprocessing of medical devices is even less feasible. The outcome quality defined as the outcome of processes, e.g., sterilization of medical devices or preparation of surfaces, can be measured. For the verification of the surface preparation markings with fluorescent dyes, the ATP test and cultural impact methods are available <TextLink reference="10"></TextLink>. All procedures have their advantages and limitations. Microbiological detection by means of microbiological samples is considered to be the gold standard, but the procedure is expensive and the results are available only after several days. The ATP method can detect bacterial adenosine triphosphate; it is fast but relatively expensive. The fluorescence method, i.e., using a pen, stamp or spray to mark a surface with a fluorescent dye, and checking with a black light lamp whether this mark has been removed by the cleaning process, is very simple, comparatively inexpensive and is suitable for directly presenting the cleaning performance. &#8211; That is, it is suitable for direct feedback and training purposes. The disadvantage is that the method only shows the quality of the cleaning (wiping with pressure) and gives no indication of the quality of disinfection. In control situations as in the present study, the result can theoretically be falsified by the fact that the marked sites were previously known to the employees of the cleaning services or the cleaning personnel themselves checked the markings with a small black light lamp of their own and then cleaned them more intensively.</Pgraph><Pgraph>In summary, the data on structural quality, process quality and outcome quality can be influenced by the institutions surveyed. Process observations are generally subject to observer bias, and all the indicators for quality assessment, including the fluorescence method used in this study, have their methodological limits. In addition, the inspections carried out by the health office can in principle only reflect the actual moments of inspection. Against this background, the legislator in Germany has rightly pointed out the responsibility of the institutions and the individuals themselves (&#167;1 <TextLink reference="19"></TextLink>) . </Pgraph><Pgraph>In general, the effect of a single measure, e.g., the disinfection of critical surfaces in the patient&#8217;s room or the reprocessing of the bathroom cannot be demonstrated directly by rates of pathogen transmission or nosocomial infections. This can only be achieved within the scope of a controlled study, if all other hygienic processes (hand hygiene, medical product reprocessing, operating procedures, etc.) are controlled. Direct comparison with wound infections or device-associated infections, which have to be monitored in the hospitals <TextLink reference="19"></TextLink> &#91;&#167;23&#93;, or with multi-drug resistant pathogens, which must be reported to the public health service <TextLink reference="20"></TextLink>, <TextLink reference="21"></TextLink>, is not suitable for this purpose because of many other additional influencing factors. </Pgraph><Pgraph>Therefore, the aim of our inspections could not be to achieve a demonstrable effect on the transmission and infection rates in the hospitals. The aim was to monitor and improve the hygienic process and to raise awareness of the importance of surface preparation. </Pgraph><Pgraph>This has been achieved. The clinics improved the quality of the structure (training of the foremen, interface plan, increase of the stipulated cleaning performance on weekends and holidays). Nevertheless, we see further need for improvement. The contractually provided time for the reprocessing of the bathrooms must be increased in general, since in both surveys, in 2014 and in 2016, the proper cleaning and disinfection of the bathrooms could not be completed in any clinic within the time commissioned. Additionally, from a hygienic view, complete cleaning restricted to certain days appears incomprehensible and unacceptable. </Pgraph><Pgraph>Significant improvements between 2014 and 2016 were also achieved in terms of process quality. The critical points were cleaned better, and the improvement was particularly good in those points which had previously been badly reprocessed. In accordance with the observed process quality, the clinics also improved the quality of the outcome. More marked points were cleaned appropriately, and again, the greatest improvements were obtained in the previously poorly prepared areas.</Pgraph><Pgraph>In various other investigations, the quality of the cleaning results measured by the fluorescence method were significantly improved by targeted interventions. In others studies, a decrease in the germ load, for example, with methicillin-resistant <Mark2>Staphylococcus aureus</Mark2> strains <TextLink reference="13"></TextLink>, and a reduction of colonizations or infections with multi-drug resistant pathogens <TextLink reference="22"></TextLink>, <TextLink reference="23"></TextLink> were demonstrated. In a further study, a significant reduction in infections were achieved by additional cleaning staff, which resulted in an estimated savings of 30,000&#8211;70,000&#163; to the clinic despite increased personnel expenses <TextLink reference="23"></TextLink>.</Pgraph><Pgraph>Inadequate cleaning can not only increase the risk of nosocomial infections and colonization with multi-drug resistant pathogens. Further negative consequences are, for example, damage to the image of the hospital, when patients complain about dirt and insufficient hygiene. According to DGKH cleaning is one of the very few areas that the patient can observe and also assess so that a hospital could profit from a qualified cleaning <TextLink reference="24"></TextLink>. Other possible consequences are legal actions because of infectious disease caused by insufficient cleaning and material damage to furniture and buildings <TextLink reference="5"></TextLink>. The DGKH notes, however, that the great importance of cleaning does not correspond to the fact that the cleaning service only has low social standing and that in the frequently outsourced cleaning companies, untrained employees, low salaries, and frequent job changes dominate.</Pgraph><Pgraph>Against this background, rethinking was demanded of the hospital management, as was qualification of the specialist for hospital cleaning, for instance, and a higher appreciation and estimation of the cleaning service <TextLink reference="25"></TextLink>. Corresponding curricula are already established in France &#91;2&#93;. Within the framework of a bundle strategy, however, not only knowledge and skills must be communicated to the cleaning staff, but feedback must be given on the quality of their work. Cleaning staff must know and feel that they are part of a team in the hospital and that they have an important and by no means negligible part in the care of patients when they clean and disinfect the surfaces <TextLink reference="25"></TextLink>, <TextLink reference="9"></TextLink>, <TextLink reference="17"></TextLink>.</Pgraph><Pgraph>New approaches to reduce germ load on surfaces, such as &#8220;self-disinfecting&#8221; surfaces by using surface materials which are either coated or mixed with metals (e.g., silver or copper) or with microcidal substances (e.g., triclosan or quarternary ammonium phosphates) are currently under investigation as a further option for the improvement of hygiene in the patient environment. Whether they meet the expectations remains to be proven, since there is still insufficient practice experience <TextLink reference="26"></TextLink>, <TextLink reference="27"></TextLink>.</Pgraph><Pgraph>All hygiene measures are only as good as the weakest link in the chain. The importance of surface preparation &#8211; with regard to the often very long persistance of germs on inanimate surfaces <TextLink reference="28"></TextLink> and especially with regard to the increase of multidirectional pathogens &#8211; should be given more attention <TextLink reference="1"></TextLink>, <TextLink reference="2"></TextLink>.</Pgraph></TextBlock>
    <TextBlock linked="yes" name="Notes">
      <MainHeadline>Notes</MainHeadline><SubHeadline>Competing interests</SubHeadline><Pgraph>The authors declare that they have no competing interests.</Pgraph></TextBlock>
    <References linked="yes">
      <Reference refNo="1">
        <RefAuthor>Exner M</RefAuthor>
        <RefTitle>Divergent opinions on sur face disinfection: myths or prevention&#63; A review of the literature</RefTitle>
        <RefYear>2007</RefYear>
        <RefJournal>GMS Krankenhaushyg Interdiszip</RefJournal>
        <RefPage>Doc19</RefPage>
        <RefTotal>Exner M. Divergent opinions on sur face disinfection: myths or prevention&#63; A review of the literature. GMS Krankenhaushyg Interdiszip. 2007;2(1):Doc19.</RefTotal>
      </Reference>
      <Reference refNo="2">
        <RefAuthor>Gebel J</RefAuthor>
        <RefAuthor>Exner M</RefAuthor>
        <RefAuthor>French G</RefAuthor>
        <RefAuthor>Chartier Y</RefAuthor>
        <RefAuthor>Christiansen B</RefAuthor>
        <RefAuthor>Gemein S</RefAuthor>
        <RefAuthor>Goroncy-Bermes P</RefAuthor>
        <RefAuthor>Hartemann P</RefAuthor>
        <RefAuthor>Heudorf U</RefAuthor>
        <RefAuthor>Kramer A</RefAuthor>
        <RefAuthor>Maillard JY</RefAuthor>
        <RefAuthor>Oltmanns P</RefAuthor>
        <RefAuthor>Rotter M</RefAuthor>
        <RefAuthor>Sonntag HG</RefAuthor>
        <RefTitle>The role of surface disinfection in infection prevention</RefTitle>
        <RefYear>2013</RefYear>
        <RefJournal>GMS Hyg Infect Control</RefJournal>
        <RefPage>Doc10</RefPage>
        <RefTotal>Gebel J, Exner M, French G, Chartier Y, Christiansen B, Gemein S, Goroncy-Bermes P, Hartemann P, Heudorf U, Kramer A, Maillard JY, Oltmanns P, Rotter M, Sonntag HG. The role of surface disinfection in infection prevention. GMS Hyg Infect Control. 2013;8(1):Doc10. DOI: 10.3205&#47;dgkh000210</RefTotal>
        <RefLink>http:&#47;&#47;dx.doi.org&#47;10.3205&#47;dgkh000210</RefLink>
      </Reference>
      <Reference refNo="3">
        <RefAuthor>Anonym</RefAuthor>
        <RefTitle>Anforderungen an die Hygiene bei der Reinigung und Desinfektion von Fl&#228;chen. Empfehlung der Kommission f&#252;r Krankenhaushygiene und Infektionspr&#228;vention beim Robert Koch-Institut (RKI)</RefTitle>
        <RefYear>2004</RefYear>
        <RefJournal>Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz</RefJournal>
        <RefPage>51-61</RefPage>
        <RefTotal>Anforderungen an die Hygiene bei der Reinigung und Desinfektion von Fl&#228;chen. Empfehlung der Kommission f&#252;r Krankenhaushygiene und Infektionspr&#228;vention beim Robert Koch-Institut (RKI) &#91;Responsibilities of public health in cleaning and disinfection of surfaces. Recommendation by the Commitee of Hospital Hygiene and Infection Control by the Robert Koch Institute&#93;. Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz. 2004 Jan;47(1):51-61. DOI: 10.1007&#47;s00103-003-0752-9</RefTotal>
        <RefLink>http:&#47;&#47;dx.doi.org&#47;10.1007&#47;s00103-003-0752-9</RefLink>
      </Reference>
      <Reference refNo="4">
        <RefAuthor>Rutala WA</RefAuthor>
        <RefAuthor>Weber DJ</RefAuthor>
        <RefAuthor> Society for Healthcare Epidemiology of America</RefAuthor>
        <RefTitle>Guideline for disinfection and sterilization of prion-contaminated medical instruments</RefTitle>
        <RefYear>2010</RefYear>
        <RefJournal>Infect Control Hosp Epidemiol</RefJournal>
        <RefPage>107-17</RefPage>
        <RefTotal>Rutala WA, Weber DJ; Society for Healthcare Epidemiology of America. Guideline for disinfection and sterilization of prion-contaminated medical instruments. Infect Control Hosp Epidemiol. 2010 Feb;31(2):107-17. DOI: 10.1086&#47;650197</RefTotal>
        <RefLink>http:&#47;&#47;dx.doi.org&#47;10.1086&#47;650197</RefLink>
      </Reference>
      <Reference refNo="5">
        <RefAuthor>DGKH Deutsche Gesellschaft f&#252;r Krankenhaushygiene</RefAuthor>
        <RefTitle>Hygienekriterien f&#252;r den Reinigungsdienst</RefTitle>
        <RefYear>2013</RefYear>
        <RefJournal>Hyg Med</RefJournal>
        <RefPage>152-7</RefPage>
        <RefTotal>DGKH Deutsche Gesellschaft f&#252;r Krankenhaushygiene. Hygienekriterien f&#252;r den Reinigungsdienst. Hyg Med. 2013;38:152-7. Available from: http:&#47;&#47;www.krankenhaushygiene.de&#47;dgkh&#47;sektionen&#47;sektion-pflege&#47;437</RefTotal>
        <RefLink>http:&#47;&#47;www.krankenhaushygiene.de&#47;dgkh&#47;sektionen&#47;sektion-pflege&#47;437</RefLink>
      </Reference>
      <Reference refNo="6">
        <RefAuthor>DGUV Deutsche Gesetzliche Unfallversicherung Spitzenverband</RefAuthor>
        <RefTitle></RefTitle>
        <RefYear>1999</RefYear>
        <RefBookTitle>DGUV-R 107-002 bisher BGR 206 (vorherige ZH 1&#47;31)</RefBookTitle>
        <RefPage></RefPage>
        <RefTotal>DGUV Deutsche Gesetzliche Unfallversicherung Spitzenverband. DGUV-R 107-002 bisher BGR 206 (vorherige ZH 1&#47;31). Regel: Desinfektionsarbeiten im Reinigungsdienst. Berlin; 1999.</RefTotal>
      </Reference>
      <Reference refNo="7">
        <RefAuthor>DGUV Deutsche Gesetzliche Unfallversicherung HVBG</RefAuthor>
        <RefTitle></RefTitle>
        <RefYear>2006</RefYear>
        <RefBookTitle>DGUV-R 101-107 vormals BGR 208 Reinigungsarbeiten mit Infektionsgefahr in medizinischen Bereichen</RefBookTitle>
        <RefPage></RefPage>
        <RefTotal>DGUV Deutsche Gesetzliche Unfallversicherung HVBG. DGUV-R 101-107 vormals BGR 208 Reinigungsarbeiten mit Infektionsgefahr in medizinischen Bereichen. K&#246;ln: Carl Heymanns Verlag; 2006.</RefTotal>
      </Reference>
      <Reference refNo="8">
        <RefAuthor>RAL G&#252;tegemeinschaft Geb&#228;udereinigung e.V. in Zusammenarbeit mit Industriegewerkschaft Bauen-Agrar-Umwelt</RefAuthor>
        <RefTitle></RefTitle>
        <RefYear>2011</RefYear>
        <RefBookTitle>Empfehlung zur Ermittlung von Leistungszahlen in der Geb&#228;udereinigung</RefBookTitle>
        <RefPage></RefPage>
        <RefTotal>RAL G&#252;tegemeinschaft Geb&#228;udereinigung e.V. in Zusammenarbeit mit Industriegewerkschaft Bauen-Agrar-Umwelt. Empfehlung zur Ermittlung von Leistungszahlen in der Geb&#228;udereinigung. Schw&#228;bisch Gm&#252;nd; 2011. Available from: http:&#47;&#47;www.gggr.de&#47;basics&#47;pdfs&#47;merkblattreihe&#47;09&#95;LZ01&#95;Leistungszahlen.pdf</RefTotal>
        <RefLink>http:&#47;&#47;www.gggr.de&#47;basics&#47;pdfs&#47;merkblattreihe&#47;09&#95;LZ01&#95;Leistungszahlen.pdf</RefLink>
      </Reference>
      <Reference refNo="9">
        <RefAuthor>Hausemann A</RefAuthor>
        <RefAuthor>Hofmann H</RefAuthor>
        <RefAuthor>Otto U</RefAuthor>
        <RefAuthor>Heudorf U</RefAuthor>
        <RefTitle>Fl&#228;chenreinigung und -desinfektion im Krankenhaus &#8211; Struktur-, Prozess- und Ergebnisqualit&#228;t: Ergebnisse der infektionshygienischen &#220;berwachung in Frankfurt am Main, 2014</RefTitle>
        <RefYear>2015</RefYear>
        <RefJournal>Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz</RefJournal>
        <RefPage>620-30</RefPage>
        <RefTotal>Hausemann A, Hofmann H, Otto U, Heudorf U. Fl&#228;chenreinigung und -desinfektion im Krankenhaus &#8211; Struktur-, Prozess- und Ergebnisqualit&#228;t: Ergebnisse der infektionshygienischen &#220;berwachung in Frankfurt am Main, 2014 &#91;Cleaning and disinfection of surfaces in hospitals: Data on structure, process and result in the Frankfurt&#47;Main Metropolitan Area&#93;. Bundesgesundheitsbl. 2015 Jun;58(6):620-30. DOI: 10.1007&#47;s00103-015-2150-5</RefTotal>
        <RefLink>http:&#47;&#47;dx.doi.org&#47;10.1007&#47;s00103-015-2150-5</RefLink>
      </Reference>
      <Reference refNo="10">
        <RefAuthor>Guh A</RefAuthor>
        <RefAuthor>Carling P</RefAuthor>
        <RefAuthor> Environmental Evaluation Workgroup</RefAuthor>
        <RefTitle></RefTitle>
        <RefYear>2010</RefYear>
        <RefBookTitle>Options for Evaluating Environmental Cleaning</RefBookTitle>
        <RefPage></RefPage>
        <RefTotal>Guh A, Carling P; Environmental Evaluation Workgroup. Options for Evaluating Environmental Cleaning. Atlanta, GA: Centers for Disease Control and Prevention; 2010. Available from:  http:&#47;&#47;www.cdc.gov&#47;HAI&#47;pdfs&#47;toolkits&#47;Environ-Cleaning-Eval-Toolkit12-2-2010.pdf</RefTotal>
        <RefLink>http:&#47;&#47;www.cdc.gov&#47;HAI&#47;pdfs&#47;toolkits&#47;Environ-Cleaning-Eval-Toolkit12-2-2010.pdf</RefLink>
      </Reference>
      <Reference refNo="11">
        <RefAuthor>Carling PC</RefAuthor>
        <RefAuthor>Briggs JL</RefAuthor>
        <RefAuthor>Perkins J</RefAuthor>
        <RefAuthor>Highlander D</RefAuthor>
        <RefTitle>Improved cleaning of patient rooms using a new targeting method</RefTitle>
        <RefYear>2006</RefYear>
        <RefJournal>Clin Infect Dis</RefJournal>
        <RefPage>385-8</RefPage>
        <RefTotal>Carling PC, Briggs JL, Perkins J, Highlander D. Improved cleaning of patient rooms using a new targeting method. Clin Infect Dis. 2006 Feb;42(3):385-8. DOI: 10.1086&#47;499361</RefTotal>
        <RefLink>http:&#47;&#47;dx.doi.org&#47;10.1086&#47;499361</RefLink>
      </Reference>
      <Reference refNo="12">
        <RefAuthor>Carling PC</RefAuthor>
        <RefAuthor>Parry MM</RefAuthor>
        <RefAuthor>Rupp ME</RefAuthor>
        <RefAuthor>Po JL</RefAuthor>
        <RefAuthor>Dick B</RefAuthor>
        <RefAuthor>Von Beheren S</RefAuthor>
        <RefAuthor> Healthcare Environmental Hygiene Study Group</RefAuthor>
        <RefTitle>Improving cleaning of the environment surrounding patients in 36 acute care hospitals</RefTitle>
        <RefYear>2008</RefYear>
        <RefJournal>Infect Control Hosp Epidemiol</RefJournal>
        <RefPage>1035-41</RefPage>
        <RefTotal>Carling PC, Parry MM, Rupp ME, Po JL, Dick B, Von Beheren S; Healthcare Environmental Hygiene Study Group. Improving cleaning of the environment surrounding patients in 36 acute care hospitals. Infect Control Hosp Epidemiol. 2008 Nov;29(11):1035-41. DOI: 10.1086&#47;591940</RefTotal>
        <RefLink>http:&#47;&#47;dx.doi.org&#47;10.1086&#47;591940</RefLink>
      </Reference>
      <Reference refNo="13">
        <RefAuthor>Goodman ER</RefAuthor>
        <RefAuthor>Platt R</RefAuthor>
        <RefAuthor>Bass R</RefAuthor>
        <RefAuthor>Onderdonk AB</RefAuthor>
        <RefAuthor>Yokoe DS</RefAuthor>
        <RefAuthor>Huang SS</RefAuthor>
        <RefTitle>Impact of an environmental cleaning intervention on the presence of methicillin-resistant Staphylococcus aureus and vancomycin-resistant enterococci on surfaces in intensive care unit rooms</RefTitle>
        <RefYear>2008</RefYear>
        <RefJournal>Infect Control Hosp Epidemiol</RefJournal>
        <RefPage>593-9</RefPage>
        <RefTotal>Goodman ER, Platt R, Bass R, Onderdonk AB, Yokoe DS, Huang SS. Impact of an environmental cleaning intervention on the presence of methicillin-resistant Staphylococcus aureus and vancomycin-resistant enterococci on surfaces in intensive care unit rooms. Infect Control Hosp Epidemiol. 2008 Jul;29(7):593-9. DOI: 10.1086&#47;588566</RefTotal>
        <RefLink>http:&#47;&#47;dx.doi.org&#47;10.1086&#47;588566</RefLink>
      </Reference>
      <Reference refNo="14">
        <RefAuthor>Blue J</RefAuthor>
        <RefAuthor>O&#39;Neill C</RefAuthor>
        <RefAuthor>Speziale P</RefAuthor>
        <RefAuthor>Revill J</RefAuthor>
        <RefAuthor>Ramage L</RefAuthor>
        <RefAuthor>Ballantyne L</RefAuthor>
        <RefTitle>Use of a fluorescent chemical as a quality indicator for a hospital cleaning program</RefTitle>
        <RefYear>2008</RefYear>
        <RefJournal>Can J Infect Control</RefJournal>
        <RefPage>216-9</RefPage>
        <RefTotal>Blue J, O&#39;Neill C, Speziale P, Revill J, Ramage L, Ballantyne L. Use of a fluorescent chemical as a quality indicator for a hospital cleaning program. Can J Infect Control. 2008;23(4):216-9.</RefTotal>
      </Reference>
      <Reference refNo="15">
        <RefAuthor>Munoz-Price LS</RefAuthor>
        <RefAuthor>Birnbach DJ</RefAuthor>
        <RefAuthor>Lubarsky DA</RefAuthor>
        <RefAuthor>Arheart KL</RefAuthor>
        <RefAuthor>Fajardo-Aquino Y</RefAuthor>
        <RefAuthor>Rosalsky M</RefAuthor>
        <RefAuthor>Cleary T</RefAuthor>
        <RefAuthor>Depascale D</RefAuthor>
        <RefAuthor>Coro G</RefAuthor>
        <RefAuthor>Namias N</RefAuthor>
        <RefAuthor>Carling P</RefAuthor>
        <RefTitle>Decreasing operating room environmental pathogen contamination through improved cleaning practice</RefTitle>
        <RefYear>2012</RefYear>
        <RefJournal>Infect Control Hosp Epidemiol</RefJournal>
        <RefPage>897-904</RefPage>
        <RefTotal>Munoz-Price LS, Birnbach DJ, Lubarsky DA, Arheart KL, Fajardo-Aquino Y, Rosalsky M, Cleary T, Depascale D, Coro G, Namias N, Carling P. Decreasing operating room environmental pathogen contamination through improved cleaning practice. Infect Control Hosp Epidemiol. 2012 Sep;33(9):897-904. DOI: 10.1086&#47;667381</RefTotal>
        <RefLink>http:&#47;&#47;dx.doi.org&#47;10.1086&#47;667381</RefLink>
      </Reference>
      <Reference refNo="16">
        <RefAuthor>Sitzlar B</RefAuthor>
        <RefAuthor>Deshpande A</RefAuthor>
        <RefAuthor>Fertelli D</RefAuthor>
        <RefAuthor>Kundrapu S</RefAuthor>
        <RefAuthor>Sethi AK</RefAuthor>
        <RefAuthor>Donskey CJ</RefAuthor>
        <RefTitle>An environmental disinfection odyssey: evaluation of sequential interventions to improve disinfection of Clostridium difficile isolation rooms</RefTitle>
        <RefYear>2013</RefYear>
        <RefJournal>Infect Control Hosp Epidemiol</RefJournal>
        <RefPage>459-65</RefPage>
        <RefTotal>Sitzlar B, Deshpande A, Fertelli D, Kundrapu S, Sethi AK, Donskey CJ. An environmental disinfection odyssey: evaluation of sequential interventions to improve disinfection of Clostridium difficile isolation rooms. Infect Control Hosp Epidemiol. 2013 May;34(5):459-65. DOI: 10.1086&#47;670217</RefTotal>
        <RefLink>http:&#47;&#47;dx.doi.org&#47;10.1086&#47;670217</RefLink>
      </Reference>
      <Reference refNo="17">
        <RefAuthor>Woltering R</RefAuthor>
        <RefAuthor>Hoffmann G</RefAuthor>
        <RefAuthor>Isermann J</RefAuthor>
        <RefAuthor>Heudorf U</RefAuthor>
        <RefTitle>Fl&#228;chenreinigung und Desinfektion im Krankenhaus. Verbesserung durch objektive &#220;berwachung und Intervention</RefTitle>
        <RefYear>2016</RefYear>
        <RefJournal>Gesundheitswesen</RefJournal>
        <RefPage>759-64</RefPage>
        <RefTotal>Woltering R, Hoffmann G, Isermann J, Heudorf U. Fl&#228;chenreinigung und Desinfektion im Krankenhaus. Verbesserung durch objektive &#220;berwachung und Intervention &#91;Surface Cleaning and Disinfection in the Hospital. Improvement by Objective Monitoring and Intervention&#93;. Gesundheitswesen. 2016 Nov;78(11):759-64. DOI: 10.1055&#47;s-0035-1545267</RefTotal>
        <RefLink>http:&#47;&#47;dx.doi.org&#47;10.1055&#47;s-0035-1545267</RefLink>
      </Reference>
      <Reference refNo="18">
        <RefAuthor>Heudorf U</RefAuthor>
        <RefAuthor>Gasteyer S</RefAuthor>
        <RefAuthor>Samoiski Y</RefAuthor>
        <RefAuthor>Voigt K</RefAuthor>
        <RefTitle>Fl&#228;chenreinigung und -desinfektion in Altenpflegeheimen. Struktur-, Prozess- und Ergebnisqualit&#228;t in Altenpflegeheimen in Frankfurt am Main, 2011</RefTitle>
        <RefYear>2012</RefYear>
        <RefJournal>Bundesgesundheitsbl</RefJournal>
        <RefPage>961-9</RefPage>
        <RefTotal>Heudorf U, Gasteyer S, Samoiski Y, Voigt K. Fl&#228;chenreinigung und -desinfektion in Altenpflegeheimen. Struktur-, Prozess- und Ergebnisqualit&#228;t in Altenpflegeheimen in Frankfurt am Main, 2011 &#91;Cleaning and disinfection in nursing homes. Data on quality of structure, process and outcome in nursing homes in Frankfurt am Main, Germany, 2011&#93;. Bundesgesundheitsbl. 2012 Aug;55(8):961-9. DOI: 10.1007&#47;s00103-012-1513-4</RefTotal>
        <RefLink>http:&#47;&#47;dx.doi.org&#47;10.1007&#47;s00103-012-1513-4</RefLink>
      </Reference>
      <Reference refNo="19">
        <RefAuthor>Anonym</RefAuthor>
        <RefTitle></RefTitle>
        <RefYear></RefYear>
        <RefBookTitle>Gesetz zur Verh&#252;tung und Bek&#228;mpfung von Infektionskrankheiten beim Menschen (Infektionsschutzgesetz - IfSG) vom 20. Juli 2000 (BGBl. I S. 1045), das zuletzt durch Artikel 1 des Gesetzes vom 17. Juli 2017 (BGBl. I S. 2615) ge&#228;ndert worden ist.</RefBookTitle>
        <RefPage></RefPage>
        <RefTotal>Gesetz zur Verh&#252;tung und Bek&#228;mpfung von Infektionskrankheiten beim Menschen (Infektionsschutzgesetz - IfSG) vom 20. Juli 2000 (BGBl. I S. 1045), das zuletzt durch Artikel 1 des Gesetzes vom 17. Juli 2017 (BGBl. I S. 2615) ge&#228;ndert worden ist. Available from: https:&#47;&#47;www.gesetze-im-internet.de&#47;ifsg&#47;IfSG.pdf Externer Link</RefTotal>
        <RefLink>https:&#47;&#47;www.gesetze-im-internet.de&#47;ifsg&#47;IfSG.pdf Externer Link</RefLink>
      </Reference>
      <Reference refNo="20">
        <RefAuthor>Anonym</RefAuthor>
        <RefTitle></RefTitle>
        <RefYear></RefYear>
        <RefBookTitle>Verordnung zur Anpassung der Meldepflichten nach dem Infektionsschutzgesetz an die epidemische Lage (IfSG-Meldepflicht-Anpassungsverordnung &#8211; IfSGmeldAnpV). Bundesgesetzblatt, 2009.</RefBookTitle>
        <RefPage></RefPage>
        <RefTotal>Verordnung zur Anpassung der Meldepflichten nach dem Infektionsschutzgesetz an die epidemische Lage (IfSG-Meldepflicht-Anpassungsverordnung &#8211; IfSGmeldAnpV). Bundesgesetzblatt, 2009.</RefTotal>
      </Reference>
      <Reference refNo="21">
        <RefAuthor>Anonym</RefAuthor>
        <RefTitle></RefTitle>
        <RefYear></RefYear>
        <RefBookTitle>Verordnung zur Anpassung der Meldepflichten nach dem Infektionsschutzgesetz an die epidemische Lage (IfSG-Meldepflicht-Anpassungsverordnung &#8211; IfSGmeldAnpV). Bundesgesetzblatt 2016, Teil I, Nr. 13, S. 515. ausgegeben zu Bonn am 31.Mai 2016.</RefBookTitle>
        <RefPage></RefPage>
        <RefTotal>Verordnung zur Anpassung der Meldepflichten nach dem Infektionsschutzgesetz an die epidemische Lage (IfSG-Meldepflicht-Anpassungsverordnung &#8211; IfSGmeldAnpV). Bundesgesetzblatt 2016, Teil I, Nr. 13, S. 515. ausgegeben zu Bonn am 31.Mai 2016. Available from: https:&#47;&#47;www.gesetze-im-internet.de&#47;ifsgmeldanpv&#47;IfSGMeldAnpV.pdf</RefTotal>
        <RefLink>https:&#47;&#47;www.gesetze-im-internet.de&#47;ifsgmeldanpv&#47;IfSGMeldAnpV.pdf</RefLink>
      </Reference>
      <Reference refNo="22">
        <RefAuthor>Datta R</RefAuthor>
        <RefAuthor>Platt R</RefAuthor>
        <RefAuthor>Yokoe DS</RefAuthor>
        <RefAuthor>Huang SS</RefAuthor>
        <RefTitle>Environmental cleaning intervention and risk of acquiring multidrug-resistant organisms from prior room occupants</RefTitle>
        <RefYear>2011</RefYear>
        <RefJournal>Arch Intern Med</RefJournal>
        <RefPage>491-4</RefPage>
        <RefTotal>Datta R, Platt R, Yokoe DS, Huang SS. Environmental cleaning intervention and risk of acquiring multidrug-resistant organisms from prior room occupants. Arch Intern Med. 2011 Mar;171(6):491-4. DOI: 10.1001&#47;archinternmed.2011.64</RefTotal>
        <RefLink>http:&#47;&#47;dx.doi.org&#47;10.1001&#47;archinternmed.2011.64</RefLink>
      </Reference>
      <Reference refNo="23">
        <RefAuthor>Dancer SJ</RefAuthor>
        <RefTitle>Hospital cleaning in the 21st century</RefTitle>
        <RefYear>2011</RefYear>
        <RefJournal>Eur J Clin Microbiol Infect Dis</RefJournal>
        <RefPage>1473-81</RefPage>
        <RefTotal>Dancer SJ. Hospital cleaning in the 21st century. Eur J Clin Microbiol Infect Dis. 2011 Dec;30(12):1473-81. DOI: 10.1007&#47;s10096-011-1250-x</RefTotal>
        <RefLink>http:&#47;&#47;dx.doi.org&#47;10.1007&#47;s10096-011-1250-x</RefLink>
      </Reference>
      <Reference refNo="24">
        <RefAuthor>DGKH Deutsche Gesellschaft f&#252;r Krankenhaushygiene</RefAuthor>
        <RefTitle>Reinigung in Krankenh&#228;usern &#8211; eine Umfrage der DGKH im Jahr 2013</RefTitle>
        <RefYear>2014</RefYear>
        <RefJournal>Hyg Med</RefJournal>
        <RefPage>232-5</RefPage>
        <RefTotal>DGKH Deutsche Gesellschaft f&#252;r Krankenhaushygiene. Reinigung in Krankenh&#228;usern &#8211; eine Umfrage der DGKH im Jahr 2013. Hyg Med. 2014;39:232-5. Available from: https:&#47;&#47;www.krankenhaushygiene.de&#47;pdfdata&#47;hm&#47;2014&#95;HM6&#95;reinigung.pdf</RefTotal>
        <RefLink>https:&#47;&#47;www.krankenhaushygiene.de&#47;pdfdata&#47;hm&#47;2014&#95;HM6&#95;reinigung.pdf</RefLink>
      </Reference>
      <Reference refNo="25">
        <RefAuthor>Havill NL</RefAuthor>
        <RefTitle>Best practices in disinfection of noncritical surfaces in the health care setting: creating a bundle for success</RefTitle>
        <RefYear>2013</RefYear>
        <RefJournal>Am J Infect Control</RefJournal>
        <RefPage>S26-30</RefPage>
        <RefTotal>Havill NL. Best practices in disinfection of noncritical surfaces in the health care setting: creating a bundle for success. Am J Infect Control. 2013 May;41(5 Suppl):S26-30. DOI: 10.1016&#47;j.ajic.2012.10.028</RefTotal>
        <RefLink>http:&#47;&#47;dx.doi.org&#47;10.1016&#47;j.ajic.2012.10.028</RefLink>
      </Reference>
      <Reference refNo="26">
        <RefAuthor>Weber DJ</RefAuthor>
        <RefAuthor>Rutala WA</RefAuthor>
        <RefTitle>Self-disinfecting surfaces: review of current methodologies and future prospects</RefTitle>
        <RefYear>2013</RefYear>
        <RefJournal>Am J Infect Control</RefJournal>
        <RefPage>S31-5</RefPage>
        <RefTotal>Weber DJ, Rutala WA. Self-disinfecting surfaces: review of current methodologies and future prospects. Am J Infect Control. 2013 May;41(5 Suppl):S31-5. DOI: 10.1016&#47;j.ajic.2012.12.005 </RefTotal>
        <RefLink>http:&#47;&#47;dx.doi.org&#47;10.1016&#47;j.ajic.2012.12.005</RefLink>
      </Reference>
      <Reference refNo="27">
        <RefAuthor>Boyce JM</RefAuthor>
        <RefTitle>Modern technologies for improving cleaning and disinfection of environmental surfaces in hospitals</RefTitle>
        <RefYear>2016</RefYear>
        <RefJournal>Antimicrob Resist Infect Control</RefJournal>
        <RefPage>10</RefPage>
        <RefTotal>Boyce JM. Modern technologies for improving cleaning and disinfection of environmental surfaces in hospitals. Antimicrob Resist Infect Control. 2016;5:10. DOI: 10.1186&#47;s13756-016-0111-x</RefTotal>
        <RefLink>http:&#47;&#47;dx.doi.org&#47;10.1186&#47;s13756-016-0111-x</RefLink>
      </Reference>
      <Reference refNo="28">
        <RefAuthor>Kramer A</RefAuthor>
        <RefAuthor>Schwebke I</RefAuthor>
        <RefAuthor>Kampf G</RefAuthor>
        <RefTitle>How long do nosocomial pathogens persist on inanimate surfaces&#63; A systematic review</RefTitle>
        <RefYear>2006</RefYear>
        <RefJournal>BMC Infect Dis</RefJournal>
        <RefPage>130-8</RefPage>
        <RefTotal>Kramer A, Schwebke I, Kampf G. How long do nosocomial pathogens persist on inanimate surfaces&#63; A systematic review. BMC Infect Dis. 2006 Aug;6:130-8. DOI: 10.1186&#47;1471-2334-6-130</RefTotal>
        <RefLink>http:&#47;&#47;dx.doi.org&#47;10.1186&#47;1471-2334-6-130</RefLink>
      </Reference>
    </References>
    <Media>
      <Tables>
        <Table format="png">
          <MediaNo>1</MediaNo>
          <MediaID>1</MediaID>
          <Caption><Pgraph><Mark1>Table 1: Structural quality for the cleaning and disinfection of surfaces in hospitals in Frankfurt&#47;Main, 2016 vs 2014</Mark1></Pgraph></Caption>
        </Table>
        <Table format="png">
          <MediaNo>2</MediaNo>
          <MediaID>2</MediaID>
          <Caption><Pgraph><Mark1>Table 2: Time for cleaning and disinfection of patient rooms and bathrooms &#8211; recommendation of the RAL, questionnaire survey of the German Society for Hospital Hygiene (DGKH) 2013, and the data of Frankfurt hospitals 2014 and 2016</Mark1></Pgraph></Caption>
        </Table>
        <Table format="png">
          <MediaNo>3</MediaNo>
          <MediaID>3</MediaID>
          <Caption><Pgraph><Mark1>Table 3: Effect of hospital cleaning as assessed by the glow-check method. Results from the hospitals in Frankfurt 2014 and 2016 compared to published data from other studies (only completely removed marks taken into account)</Mark1></Pgraph></Caption>
        </Table>
        <NoOfTables>3</NoOfTables>
      </Tables>
      <Figures>
        <Figure format="png" height="552" width="901">
          <MediaNo>1</MediaNo>
          <MediaID>1</MediaID>
          <Caption><Pgraph><Mark1>Figure 1: Time commissioned and time needed for the reprocessing of patients&#8217; rooms and bathrooms in the hospitals in Frankfurt&#47;Main &#8211; 2016 vs 2014</Mark1></Pgraph></Caption>
        </Figure>
        <Figure format="png" height="437" width="756">
          <MediaNo>2</MediaNo>
          <MediaID>2</MediaID>
          <Caption><Pgraph><Mark1>Figure 2: Monitoring quality of process of the cleaning and disinfection in hospitals in Frankfurt&#47;Main, 2014 and 2016, by visual observation according to the different sites &#8211; percent of properly cleaned sites</Mark1></Pgraph></Caption>
        </Figure>
        <Figure format="png" height="442" width="756">
          <MediaNo>3</MediaNo>
          <MediaID>3</MediaID>
          <Caption><Pgraph><Mark1>Figure 3: Monitoring the outcome quality of cleaning and disinfection in hospitals in Frankfurt&#47;Main, 2014 and 2016, by the glow-check method according to the different sites &#8211; percent compliance in different hospitals</Mark1></Pgraph></Caption>
        </Figure>
        <Figure format="png" height="445" width="753">
          <MediaNo>4</MediaNo>
          <MediaID>4</MediaID>
          <Caption><Pgraph><Mark1>Figure 4: Monitoring the effect of the cleaning and disinfection in hospitals in Frankfurt&#47;Main, 2014 and 2016, by the glow-check method on different sites &#8211; percent of properly cleaned sites</Mark1></Pgraph></Caption>
        </Figure>
        <NoOfPictures>4</NoOfPictures>
      </Figures>
      <InlineFigures>
        <NoOfPictures>0</NoOfPictures>
      </InlineFigures>
      <Attachments>
        <NoOfAttachments>0</NoOfAttachments>
      </Attachments>
    </Media>
  </OrigData>
</GmsArticle>