<?xml version="1.0" encoding="iso-8859-1" standalone="no"?>
<!DOCTYPE GmsArticle SYSTEM "http://www.egms.de/dtd/2.0.34/GmsArticle.dtd">
<GmsArticle xmlns:xlink="http://www.w3.org/1999/xlink">
  <MetaData>
    <Identifier>zma001784</Identifier>
    <IdentifierDoi>10.3205/zma001784</IdentifierDoi>
    <IdentifierUrn>urn:nbn:de:0183-zma0017840</IdentifierUrn>
    <ArticleType language="en">project report</ArticleType>
    <ArticleType language="de">Projektbericht</ArticleType>
    <TitleGroup>
      <Title language="en">Development and evaluation of the SimArena Magdeburg (SAM): A randomized controlled trial of the impact of a low-cost 180&#176; simulation arena for emergency medical simulation training on stress perception and the associated resuscitation quality in medical students</Title>
      <TitleTranslated language="de">Entwicklung und Evaluation der SimArena Magdeburg (SAM): Eine randomisierte kontrollierte Studie zu den Auswirkungen einer kosteng&#252;nstigen 180&#176; Simulationsarena f&#252;r notfallmedizinisches Simulationstraining auf das Stressempfinden und die damit verbundene Reanimationsqualit&#228;t von Medizinstudierenden</TitleTranslated>
    </TitleGroup>
    <CreatorList>
      <Creator>
        <PersonNames>
          <Lastname>Leschowski</Lastname>
          <LastnameHeading>Leschowski</LastnameHeading>
          <Firstname>Niklas</Firstname>
          <Initials>N</Initials>
        </PersonNames>
        <Address language="en">Asklepios Clinic Wandsbek, Central Emergency Department, Alphonsstra&#223;e 14, D-22043 Hamburg, Germany, Phone: &#43;49(0)175&#47;6850260<Affiliation>Asklepios Clinic Wandsbek, Central Emergency Department, Hamburg, Germany</Affiliation></Address>
        <Address language="de">Asklepios Klinik Wandsbek, Zentrum f&#252;r Klinische Notfall- und Akutmedizin, Alphonsstra&#223;e 14, 22043 Hamburg, Deutschland, Tel.: &#43;49(0)175&#47;6850260<Affiliation>Asklepios Klinik Wandsbek, Zentrum f&#252;r Klinische Notfall- und Akutmedizin, Hamburg, Deutschland</Affiliation></Address>
        <Email>niklas.leschowski&#64;t-online.de</Email>
        <Creatorrole corresponding="yes" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Brinkema</Lastname>
          <LastnameHeading>Brinkema</LastnameHeading>
          <Firstname>Hanno</Firstname>
          <Initials>H</Initials>
        </PersonNames>
        <Address language="en">
          <Affiliation>Cologne-Merheim Medical Center, Department for Orthopedics, Plastic Surgery, Trauma Surgery, and Sports Traumatology, Cologne, Germany</Affiliation>
        </Address>
        <Address language="de">
          <Affiliation>Krankenhaus K&#246;ln-Merheim, Zentrum f&#252;r Orthop&#228;die, Plastische Chirurgie, Unfallchirurgie und Sporttraumatologie, K&#246;ln, Deutschland</Affiliation>
        </Address>
        <Email>hannobrinkema&#64;web.de</Email>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Darius</Lastname>
          <LastnameHeading>Darius</LastnameHeading>
          <Firstname>Sabine</Firstname>
          <Initials>S</Initials>
          <AcademicTitle>Dr. med.</AcademicTitle>
        </PersonNames>
        <Address language="en">
          <Affiliation>Otto-von-Guericke University Magdeburg, Faculty of Medicine, Occupational Medicine, Magdeburg, Germany</Affiliation>
        </Address>
        <Address language="de">
          <Affiliation>Otto-von-Guericke-Universit&#228;t Magdeburg, Medizinische Fakult&#228;t, Bereich Arbeitsmedizin, Magdeburg, Deutschland</Affiliation>
        </Address>
        <Email>sabine.darius&#64;med.ovgu.de</Email>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Wolter</Lastname>
          <LastnameHeading>Wolter</LastnameHeading>
          <Firstname>Juliane</Firstname>
          <Initials>J</Initials>
          <AcademicTitle>Dr. rer. nat.</AcademicTitle>
        </PersonNames>
        <Address language="en">
          <Affiliation>Otto-von-Guericke University Magdeburg, Faculty of Medicine, Institute for Clinical Chemistry and Pathobiochemistry, Magdeburg, Germany</Affiliation>
        </Address>
        <Address language="de">
          <Affiliation>Otto-von-Guericke-Universit&#228;t Magdeburg, Medizinische Fakult&#228;t, Institut f&#252;r Klinische Chemie und Pathobiochemie, Magdeburg, Deutschland</Affiliation>
        </Address>
        <Email>juliane.wolter&#64;med.ovgu.de</Email>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>B&#246;ckelmann</Lastname>
          <LastnameHeading>B&#246;ckelmann</LastnameHeading>
          <Firstname>Irina</Firstname>
          <Initials>I</Initials>
          <AcademicTitle>Prof. Dr. med.</AcademicTitle>
        </PersonNames>
        <Address language="en">
          <Affiliation>Otto-von-Guericke University Magdeburg, Faculty of Medicine, Occupational Medicine, Magdeburg, Germany</Affiliation>
        </Address>
        <Address language="de">
          <Affiliation>Otto-von-Guericke-Universit&#228;t Magdeburg, Medizinische Fakult&#228;t, Bereich Arbeitsmedizin, Magdeburg, Deutschland</Affiliation>
        </Address>
        <Email>irina.boeckelmann&#64;med.ovgu.de</Email>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Borucki</Lastname>
          <LastnameHeading>Borucki</LastnameHeading>
          <Firstname>Katrin</Firstname>
          <Initials>K</Initials>
          <AcademicTitle>Dr. med.</AcademicTitle>
        </PersonNames>
        <Address language="en">
          <Affiliation>Otto-von-Guericke University Magdeburg, Faculty of Medicine, Institute for Clinical Chemistry and Pathobiochemistry, Magdeburg, Germany</Affiliation>
        </Address>
        <Address language="de">
          <Affiliation>Otto-von-Guericke-Universit&#228;t Magdeburg, Medizinische Fakult&#228;t, Institut f&#252;r Klinische Chemie und Pathobiochemie, Magdeburg, Deutschland</Affiliation>
        </Address>
        <Email>katrin.borucki&#64;med.ovgu.de</Email>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Sauer</Lastname>
          <LastnameHeading>Sauer</LastnameHeading>
          <Firstname>Dorothea</Firstname>
          <Initials>D</Initials>
          <AcademicTitle>PD Dr. med.</AcademicTitle>
        </PersonNames>
        <Address language="en">
          <Affiliation>Asklepios Clinic Wandsbek, Central Emergency Department, Hamburg, Germany</Affiliation>
        </Address>
        <Address language="de">
          <Affiliation>Asklepios Klinik Wandsbek, Zentrum f&#252;r Klinische Notfall- und Akutmedizin, Hamburg, Deutschland</Affiliation>
        </Address>
        <Email>dr.dorothea.sauer&#64;gmail.com</Email>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Braun-Dullaeus</Lastname>
          <LastnameHeading>Braun-Dullaeus</LastnameHeading>
          <Firstname>R&#252;diger Christian</Firstname>
          <Initials>RC</Initials>
          <AcademicTitle>Prof. Dr. med.</AcademicTitle>
        </PersonNames>
        <Address language="en">
          <Affiliation>University Hospital Magdeburg, Department of Cardiology and Angiology, Magdeburg, Germany</Affiliation>
        </Address>
        <Address language="de">
          <Affiliation>Universit&#228;tsklinikum Magdeburg, Klinik f&#252;r Kardiologie und Angiologie, Magdeburg, Deutschland</Affiliation>
        </Address>
        <Email>r.braun-dullaeus&#64;med.ovgu.de</Email>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
    </CreatorList>
    <PublisherList>
      <Publisher>
        <Corporation>
          <Corporatename>German Medical Science GMS Publishing House</Corporatename>
        </Corporation>
        <Address>D&#252;sseldorf</Address>
      </Publisher>
    </PublisherList>
    <SubjectGroup>
      <SubjectheadingDDB>610</SubjectheadingDDB>
      <Keyword language="en">simulation</Keyword>
      <Keyword language="en">simulated environment</Keyword>
      <Keyword language="en">simulation arena</Keyword>
      <Keyword language="en">medical education</Keyword>
      <Keyword language="en">emergency medicine</Keyword>
      <Keyword language="en">virtual reality</Keyword>
      <Keyword language="de">Simulation</Keyword>
      <Keyword language="de">Simulationsumgebung</Keyword>
      <Keyword language="de">Simulationsarena</Keyword>
      <Keyword language="de">medizinische Ausbildung</Keyword>
      <Keyword language="de">Notfallmedizin</Keyword>
      <Keyword language="de">virtuelle Realit&#228;t</Keyword>
      <SectionHeading language="en">simulation</SectionHeading>
      <SectionHeading language="de">Simulation</SectionHeading>
    </SubjectGroup>
    <DateReceived>20241110</DateReceived>
    <DateRevised>20250622</DateRevised>
    <DateAccepted>20250728</DateAccepted>
    <DatePublishedList>
      <DatePublished>20251117</DatePublished>
    </DatePublishedList>
    <Language>engl</Language>
    <LanguageTranslation>germ</LanguageTranslation>
    <License license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/4.0/">
      <AltText language="en">This is an Open Access article distributed under the terms of the Creative Commons Attribution 4.0 License.</AltText>
      <AltText language="de">Dieser Artikel ist ein Open-Access-Artikel und steht unter den Lizenzbedingungen der Creative Commons Attribution 4.0 License (Namensnennung).</AltText>
    </License>
    <SourceGroup>
      <Journal>
        <ISSN>2366-5017</ISSN>
        <Volume>42</Volume>
        <Issue>5</Issue>
        <JournalTitle>GMS Journal for Medical Education</JournalTitle>
        <JournalTitleAbbr>GMS J Med Educ</JournalTitleAbbr>
      </Journal>
    </SourceGroup>
    <ArticleNo>60</ArticleNo>
  </MetaData>
  <OrigData>
    <Abstract language="de" linked="yes"><Pgraph><Mark1>Einleitung: </Mark1>Simulationsarenen, in denen Videoaufnahmen von mehreren Projektoren auf ma&#223;gefertigte gebogene Leinw&#228;nde projiziert werden, um die Realit&#228;tsn&#228;he von notfallmedizinischen Simulationen zu erh&#246;hen, waren bisher mit hohen Entwicklungskosten von &#252;ber 100.000 Euro verbunden. Die Ziele dieses Forschungsprojektes waren (1) die Entwicklung einer kosteng&#252;nstigen Simulationsarena, (2) die Untersuchung, ob die Simulationsarena die Realit&#228;tsn&#228;he der Simulationen erh&#246;ht und (3) ob sie einen Einfluss auf das Stressempfinden und die damit verbundene Reanimationsqualit&#228;t hat.</Pgraph><Pgraph><Mark1>Methoden:</Mark1> In einer Pilotstudie wurde im Rahmen zweier studentischer Lehrveranstaltungen anhand von Frageb&#246;gen die Zufriedenheit, die Realit&#228;tsn&#228;he und das subjektive Stressempfinden untersucht. In der randomisierten kontrollierten SIMARENA-Studie wurde bei Studierenden des dritten bis sechsten Studienjahres das subjektive Stressempfinden und die subjektive Reanimationsqualit&#228;t mittels einer visuellen Analogskala (VAS), die objektive Reanimationsqualit&#228;t mittels eines Reanimations-Feedback-Systems und das objektive Stressempfinden mittels der kardialen Reaktivit&#228;t untersucht. </Pgraph><Pgraph><Mark1>Ergebnisse: </Mark1>Die Entwicklungskosten der SimArena Magdeburg (SAM) beliefen sich auf 7.726,50 Euro. Fast alle Teilnehmenden waren sich einig, dass die SAM zur Wahrnehmung einer realistischen Umgebung beigetragen hat. Es gab einen signifikanten Unterschied beim subjektiven Stressempfinden. Auch die kardiale Reaktivit&#228;t war bei Verwendung der SAM signifikant h&#246;her. Die subjektive und objektive Reanimationsqualit&#228;t zeigte keinen signifikanten Unterschied.</Pgraph><Pgraph><Mark1>Schlussfolgerungen:</Mark1> Die SAM ist die erste kosteng&#252;nstige 180&#176; Simulationsarena, die notfallmedizinische Simulationen in einer realistischen, sicheren, schnell austauschbaren und standardisierten Umgebung erm&#246;glicht. Sie erh&#246;ht das Stressempfinden, ohne die Reanimationsqualit&#228;t zu beeintr&#228;chtigen und bietet eine optimale Lernumgebung, in der das Stressniveau durch verschiedene Parameter an die Lernziele der Teilnehmenden angepasst werden kann.</Pgraph></Abstract>
    <Abstract language="en" linked="yes"><Pgraph><Mark1>Introduction: </Mark1>Simulation arenas, in which video recordings from multiple projectors are projected onto curved screens to increase the realism of emergency medical simulations, have so far been associated with high development costs of more than 100,000 euros. The objectives of this study were (1) to develop a cost-effective simulation arena, (2) to determine whether the simulation arena increases the realism of simulations and (3) whether it has an impact on the perception of stress and the associated quality of resuscitation.</Pgraph><Pgraph><Mark1>Methods: </Mark1>A pilot study was conducted to assess the level of satisfaction, realism, and perceived stress in two student courses using a questionnaire. In the randomized controlled SIMARENA trial, third to sixth year students were assessed for subjective stress and subjective resuscitation quality by a visual analogue scale (VAS), objective resuscitation quality by a resuscitation feedback system, and objective stress by cardiac reactivity.</Pgraph><Pgraph><Mark1>Results: </Mark1>The development costs of the SimArena Magdeburg (SAM) amounted to 7,726.50 euros. Almost all participants agreed that the SAM contributed to the perception of a realistic environment. There was a significant difference in perceived stress. Cardiac reactivity was also significantly higher when using the SAM. The subjective and objective resuscitation quality showed no significant difference.</Pgraph><Pgraph><Mark1>Conclusions: </Mark1>The SAM is the first low-cost 180&#176; simulation arena that enables emergency medical simulations in a realistic, secure, quickly interchangeable, and standardized environment. It causes an increased stress perception without reducing the quality of resuscitation, providing an optimal learning environment in which stress levels can be tailored to the participants&#39; learning objectives through various parameters.</Pgraph></Abstract>
    <TextBlock name="1. Introduction" linked="yes" language="en">
      <MainHeadline>1. Introduction</MainHeadline><Pgraph>Simulation arenas, that project videos from multiple projectors onto curved screens, to enable a realistic, quickly interchangeable, secure, and standardized environment representation for emergency medical simulations are rarely used in emergency medical education worldwide due to the high development costs, which can exceed 100,000 euros <TextLink reference="1"></TextLink>, <TextLink reference="2"></TextLink>, <TextLink reference="3"></TextLink>, <TextLink reference="4"></TextLink>, <TextLink reference="5"></TextLink>, <TextLink reference="6"></TextLink>, <TextLink reference="7"></TextLink>, <TextLink reference="8"></TextLink>, <TextLink reference="9"></TextLink>, <TextLink reference="10"></TextLink>. The semicircular training rooms provide a protected and secure environment and allow the simulation of the wide range of locations and environmental conditions in which emergency medical personnel must operate, but where simulations are not regularly possible, such as busy roads, highways, railways, and even military battlefields <TextLink reference="1"></TextLink>, <TextLink reference="2"></TextLink>, <TextLink reference="3"></TextLink>, <TextLink reference="4"></TextLink>, <TextLink reference="5"></TextLink>, <TextLink reference="6"></TextLink>, <TextLink reference="7"></TextLink>, <TextLink reference="8"></TextLink>, <TextLink reference="9"></TextLink>, <TextLink reference="10"></TextLink>, <TextLink reference="11"></TextLink>, <TextLink reference="12"></TextLink>, <TextLink reference="13"></TextLink>. Using video projection, environmental sounds, and flexible props, different scenarios can be quickly interchanged to create a standardized, realistic environment for learning and exams <TextLink reference="1"></TextLink>, <TextLink reference="3"></TextLink>, <TextLink reference="7"></TextLink>, <TextLink reference="9"></TextLink>, <TextLink reference="10"></TextLink>, <TextLink reference="13"></TextLink>. In addition, environmental simulation can create realistic stress conditions, restrict the regular workflow and challenge the teamwork and interpersonal communication <TextLink reference="9"></TextLink>, <TextLink reference="10"></TextLink>, <TextLink reference="13"></TextLink>, <TextLink reference="14"></TextLink>, <TextLink reference="15"></TextLink>. The high degree of realism in simulation training is of pertinence, as it aims to attain a high level of competence through the seamless integration of learned techniques into daily life and clinical situations <TextLink reference="10"></TextLink>, <TextLink reference="16"></TextLink>. In addition, it can help develop a certain level of stress resistance. Processes such as communication, leadership, and decision-making under stress can be experienced in a targeted manner, while at the same time emphasizing the importance of complying with medical and non-medical safety standards <TextLink reference="9"></TextLink>, <TextLink reference="10"></TextLink>, <TextLink reference="15"></TextLink>. There is evidence that stress can potentially reduce attention resources, increase distractibility, and impair resuscitation performance <TextLink reference="17"></TextLink>. </Pgraph><Pgraph>The overall objective of this research project was to develop the low-cost simulation arena &#8220;SimArena Magdeburg&#8221; (SAM) and to investigate the added value of simulation arenas, especially in comparison to frequent simulations in seminar rooms without environmental representation. As part of a pilot project, the satisfaction and subjective perception of the realism of the SAM&#39;s environment representation were to be investigated using a subjective questionnaire. Since studies have so far mainly used subjective questionnaires to investigate the effects of simulation arenas on participants in simulation training, a randomized controlled trial was designed to investigate how the use of SAM during a five-minute lay resuscitation affects the subjective and objective stress perception as well as the subjective and objective resuscitation quality of medical students. Our hypotheses were that the SAM would provide a satisfactory and realistic representation of the environment and that the subjective and objective stress levels of medical students during a 5-minute lay resuscitation would increase more and the subjective and objective resuscitation quality would decrease more with the SAM than without the SAM.</Pgraph></TextBlock>
    <TextBlock name="1. Einleitung" linked="yes" language="de">
      <MainHeadline>1. Einleitung</MainHeadline><Pgraph>Simulationsarenen, in denen Videoaufnahmen von mehreren Projektoren auf ma&#223;gefertigte gebogene Leinw&#228;nde projiziert werden, um eine realistische, schnell austauschbare, sichere und standardisierte Umgebungsdarstellung f&#252;r notfallmedizinische Simulationen zu erm&#246;glichen, werden weltweit aufgrund der hohen Entwicklungskosten von &#252;ber 100.000 Euro nur selten in der notfallmedizinischen Ausbildung eingesetzt <TextLink reference="1"></TextLink>, <TextLink reference="2"></TextLink>, <TextLink reference="3"></TextLink>, <TextLink reference="4"></TextLink>, <TextLink reference="5"></TextLink>, <TextLink reference="6"></TextLink>, <TextLink reference="7"></TextLink>, <TextLink reference="8"></TextLink>, <TextLink reference="9"></TextLink>, <TextLink reference="10"></TextLink>. Die halbrunden Trainingsr&#228;ume bieten eine gesch&#252;tzte und sichere Umgebung und erm&#246;glichen die Simulation einer Vielzahl von Orten und Umgebungsbedingungen, in denen Rettungskr&#228;fte t&#228;tig sein m&#252;ssen, in denen jedoch keine regelm&#228;&#223;igen Simulationen m&#246;glich sind, wie z. B. stark befahrene Stra&#223;en, Autobahnen, Eisenbahnstrecken und sogar milit&#228;rische Schlachtfelder <TextLink reference="1"></TextLink>, <TextLink reference="2"></TextLink>, <TextLink reference="3"></TextLink>, <TextLink reference="4"></TextLink>, <TextLink reference="5"></TextLink>, <TextLink reference="6"></TextLink>, <TextLink reference="7"></TextLink>, <TextLink reference="8"></TextLink>, <TextLink reference="9"></TextLink>, <TextLink reference="10"></TextLink>, <TextLink reference="11"></TextLink>, <TextLink reference="12"></TextLink>, <TextLink reference="13"></TextLink>. Mithilfe von Videoprojektionen, Umgebungsger&#228;uschen und flexiblen Requisiten lassen sich verschiedene Szenarien schnell austauschen, um eine standardisierte und realistische Umgebung f&#252;r Lernsituationen und Pr&#252;fungen zu schaffen <TextLink reference="1"></TextLink>, <TextLink reference="3"></TextLink>, <TextLink reference="7"></TextLink>, <TextLink reference="9"></TextLink>, <TextLink reference="10"></TextLink>, <TextLink reference="13"></TextLink>. </Pgraph><Pgraph>Dar&#252;ber hinaus kann die Umgebungssimulation realistische Stressbedingungen schaffen, den regul&#228;ren Arbeitsablauf einschr&#228;nken und die Teamarbeit und zwischenmenschliche Kommunikation herausfordern <TextLink reference="9"></TextLink>, <TextLink reference="10"></TextLink>, <TextLink reference="13"></TextLink>, <TextLink reference="14"></TextLink>, <TextLink reference="15"></TextLink>. Die hohe Realit&#228;tsn&#228;he der Simulationen ist von Bedeutung, da sie darauf abzielt, durch die nahtlose Integration der erlernten Techniken in den Alltag und in klinische Situationen ein hohes Ma&#223; an Kompetenz zu erreichen <TextLink reference="10"></TextLink>, <TextLink reference="16"></TextLink>. Dar&#252;ber hinaus kann die Entwicklung einer gewissen Stressresistenz erm&#246;glicht werden. Gezielt k&#246;nnen Prozesse wie Kommunikation, F&#252;hren und Entscheiden unter Stress erlebt und gleichzeitig die notwendige Einhaltung medizinischer und nichtmedizinischer Sicherheitsstandards verdeutlicht werden <TextLink reference="9"></TextLink>, <TextLink reference="10"></TextLink>, <TextLink reference="15"></TextLink>. Es gibt Hinweise darauf, dass Stress die Aufmerksamkeitsressourcen potenziell verringern, die Ablenkbarkeit erh&#246;hen und die Reanimationsleistung beeintr&#228;chtigen kann <TextLink reference="17"></TextLink>. </Pgraph><Pgraph>Das &#252;bergeordnete Ziel dieses Forschungsprojekts war die Entwicklung der kosteng&#252;nstigen Simulationsarena &#8222;SimArena Magdeburg&#8220; (SAM) und die Untersuchung des Mehrwerts von Simulationsarenen, insbesondere im Vergleich zu h&#228;ufigen Simulationen in Seminarr&#228;umen ohne Umgebungsdarstellung. Im Rahmen eines Pilotprojekts sollten die Zufriedenheit und die subjektiv wahrgenommene Realit&#228;tsn&#228;he der Umgebungsdarstellung durch die SAM mithilfe eines Fragebogens untersucht werden. Da Studien bisher haupts&#228;chlich subjektive Frageb&#246;gen verwendet haben, um die Auswirkungen von Simulationsarenen auf Teilnehmende von Simulationstrainings zu untersuchen, wurde eine randomisierte kontrollierte Studie konzipiert, um zu untersuchen, wie sich der Einsatz der SAM w&#228;hrend einer f&#252;nfmin&#252;tigen Laien-Reanimation auf das subjektive und objektive Stressempfinden sowie auf die subjektive und objektive Reanimationsqualit&#228;t von Medizinstudierenden auswirkt. Unsere Hypothesen lauteten, dass die SAM eine zufriedenstellende und realistische Umgebungsdarstellung bietet und dass das subjektive und objektive Stressempfinden von Medizinstudierenden w&#228;hrend einer f&#252;nfmin&#252;tigen Laienreanimation mit Einsatz der SAM st&#228;rker ansteigt und die subjektive und objektive Reanimationsqualit&#228;t st&#228;rker abnimmt als ohne Einsatz der SAM.</Pgraph></TextBlock>
    <TextBlock name="2. Methods" linked="yes" language="en">
      <MainHeadline>2. Methods</MainHeadline><SubHeadline>2.1. Development</SubHeadline><Pgraph>The projection screen of the SAM is a semi-circular, 180&#176; curved wooden construction consisting of several segments and coated with four millimeters of solid white paint. The short-throw projectors and ceiling mounts were placed so far away from the screen that both short-throw projectors illuminated all parts of the screen (see figure 1 <ImgLink imgNo="1" imgType="figure" /> and figure 2 <ImgLink imgNo="2" imgType="figure" />). To combine the two independent projections of the short-throw projectors into a single projection, both short-throw projectors were synchronized using the NVIDIA Surround feature in the 3D Settings menu of the NVIDIA system control. The Immersive Display software allowed the projection to be adjusted to fit the curvature and dimensions of the projection surface (see figure 3 <ImgLink imgNo="3" imgType="figure" />). For the panoramic video recordings, the Nikon KeyMission 360 4K was mounted on a tripod one meter above the ground and a five-minute recording was started. To convert the 360&#176; panoramic video footage into 180&#176; panoramic video footage, it was cropped to a horizontal angle of 180&#176; using the video editing program iMovie. Additional sounds were added to the videos as needed. The video recordings can be adjusted to the size of the screen and played back using the QuickTime or VLC player. A dark gray carpet was installed to provide a color-coordinated background for the environment simulation and to make the participants&#8217; knees more comfortable. In addition, a fan to simulate wind, a fog machine and a flash strobe were connected to the SAM via a radio switch set (see table 1 <ImgLink imgNo="1" imgType="table" />).</Pgraph><SubHeadline>2.2. Pilot study</SubHeadline><Pgraph>To investigate whether the goal of a realistic representation of the environment is achieved by the SAM and whether the SAM has an influence on the perception of stress the SAM was evaluated in a pilot study during two courses on polytrauma care at the Magdeburg Training Center for Basic Medical Skills (MAMBA Skillslab). Two simulation scenarios were performed in SAM environments and two simulation scenarios were performed in real-world environments not represented by the SAM. The SAM simulated a scene in a forest and a scene on a busy road. A stairwell and a street in front of the training center served as real environments. In all the simulations, participants had to care for a Laerdal Resusci Anne QCPR full body with airway head in a polytrauma scenario. Following the scenarios, all participants completed a questionnaire consisting of eight questions using Likert scales (see table 2 <ImgLink imgNo="2" imgType="table" />). Three questions were only added in the second course.</Pgraph><SubHeadline>2.3. SIMARENA trial</SubHeadline><SubHeadline2>2.3.1. Subjective perception of stress</SubHeadline2><Pgraph>A visual analog scale (VAS-S) ranging from 0 mm (&#8220;no stress&#8221;) to 100 mm (&#8220;maximum stress&#8221;) served as the primary target measure of subjective stress perception. The secondary outcome measure was the State-Trait-Anxiety Inventory (STAI), which uses two questionnaires to distinguish between current anxiety, which varies in intensity over time and across situations (STAI-S), and habitual anxiety (STAI-T) <TextLink reference="18"></TextLink>. The questionnaires each consist of 20 items on a four-point response scale. The values of the items are added together, resulting in two total scores between 20 and 80 <TextLink reference="18"></TextLink>. The factors &#8220;current ability to act&#8221; (BEA), &#8220;emotional tension&#8221; (TEN), &#8220;emotional evaluation of the situation&#8221; (STIM), and &#8220;self-control&#8221; (SPAN) of the Nitsch Self-State Scale (EZ) were used as additional secondary outcome measures <TextLink reference="19"></TextLink>, <TextLink reference="20"></TextLink>. The EZ consists of 40 characteristic words that are rated on a 6-point ordinal scale from 1 &#8220;hardly&#8221; to 6 &#8220;completely&#8221;. After converting the elementary values into area-transformed z&#39;-values, these were summed and transformed into 14 binary factors in a 3-stage hierarchy <TextLink reference="19"></TextLink>, <TextLink reference="20"></TextLink>. The scale of 1 to 9 is designed so that a higher value for each factor indicates a more positive subjective assessment of one&#8217;s ability to act <TextLink reference="20"></TextLink>. The parameter &#8220;current motivation to act&#8221; (MOT) was also used to determine the motivation status of the test subjects prior to the study intervention <TextLink reference="20"></TextLink>.</Pgraph><SubHeadline2>2.3.2. Objective perception of stress</SubHeadline2><Pgraph>Cardiac reactivity (CR), defined as the difference between the mean heart rate during resuscitation and a baseline period before resuscitation, was used as the primary objective measure of objective stress perception. For this purpose, continuous electrocardiography was performed using the Holter ECG medilog AR12plus (SCHILLER Medizintechnik GmbH, Obfelden, Switzerland). Using the medilog DARWIN2 software (SCHILLER Medizintechnik GmbH), electrical cardiac activity was automatically detected via three leads, verified, and incorrectly detected cardiac activity was manually corrected. The secondary outcome measure of objective stress perception was the heart rate (HR) and the heart rate variability (HRV) parameters SDNN (Standard Deviation of NN intervals), SNS Index (Sympathetic Nervous System Index), SI (Stress Index) and SD2 (Standard Deviation of the distances of the points from the major axis) during resuscitation. HRV analysis was performed using the Kubios HRV version 2.0 software (Biosignal Analysis and Medical Imaging Group, University of Kuopio, Finland). Respiratory rate (RR) was also used as a secondary outcome measure immediately after resuscitation and was continuously recorded by the Vernier Go Direct Respiratory Belt and analyzed using Vernier Graphical Analysis&#8482; 4 software. Finally, the ratio of salivary alpha-amylase activity (sAA) immediately after resuscitation to a resting value before resuscitation was considered as another secondary outcome measure of objective stress perception. For this purpose, three saliva samples were collected from the subjects using saliva cups (SARSTEDT). The participants were instructed to place the saliva collection device&#39;s absorbent roll in one of their cheeks for two minutes without chewing or speaking <TextLink reference="21"></TextLink>, <TextLink reference="22"></TextLink>, <TextLink reference="23"></TextLink>. After being stored at -20&#176;C for a maximum of three days, the samples were subjected to automated in-vitro testing using the Roche Cobas6000 <TextLink reference="23"></TextLink>, <TextLink reference="24"></TextLink>, <TextLink reference="25"></TextLink>. The samples were thawed at room temperature and centrifuged at 4000 revolutions per minute for ten minutes at room temperature. 10 &#956;l of the sample were mixed with 990 &#956;l of distilled water. After calibrating the measurement system with distilled water and a Roche calibration standard, the measurement was started using the c501 module in serum mode <TextLink reference="24"></TextLink>. The Roche cobas c systems automatically calculate the analytical activity of the sample <TextLink reference="24"></TextLink>. The conversion factor was: U&#47;Lx0.0167&#61;&#956;kat&#47;L. The kinetic method is based on the cleavage of 4,6-ethylidene-(G7)-1,4-nitrophenyl-(G1)-&#945;,D-maltoheptaoside (Ethylidene Protected Substrate&#61;EPS) by alpha-amylase, followed by the hydrolysis of all cleavage products using alpha-glucosidase (auxiliary enzyme) to p-nitrophenol (100&#37; chromophore release) <TextLink reference="24"></TextLink>. The color intensity of the formed p-nitrophenol was directly proportional to the alpha-amylase activity and was determined by measuring the increase in extinction <TextLink reference="24"></TextLink>.</Pgraph><SubHeadline2>2.3.3. Subjective quality of the resuscitation</SubHeadline2><Pgraph>The primary target of subjective resuscitation quality was assessed using a visual analog scale ranging from 0 mm (&#8220;poor resuscitation&#8221;) to 100 mm (&#8220;excellent resuscitation&#8221;), which was completed by the subjects immediately after resuscitation.</Pgraph><SubHeadline2>2.3.4. Objective quality of the resuscitation</SubHeadline2><Pgraph>The primary objective measure of the quality of resuscitation was the total score (TOTAL), which was calculated by the Laerdal Resusci Anne QCPR and the Laerdal SimPad PLUS SkillReporter immediately after resuscitation as an overall value of resuscitation performance based on the parameters of compression, ventilation, and time with CPR activity <TextLink reference="26"></TextLink>. The algorithm used was developed by Laerdal Medical in close collaboration with members of the Emergency Cardiovascular Care (ECC) Subcommittee of the American Heart Association (AHA) and co-authors of the AHA Guidelines for Cardiopulmonary Resuscitation <TextLink reference="27"></TextLink>. In addition, several secondary resuscitation parameters were also measured (see table 3 <ImgLink imgNo="3" imgType="table" />) <TextLink reference="26"></TextLink>. As a further secondary objective, a resuscitation checklist was defined (see table 4 <ImgLink imgNo="4" imgType="table" />). This checklist was completed by the examiner during resuscitation and was based on the recommendations for lay resuscitation (&#8220;BLS procedure for adults&#8221;) of the 2015 guidelines of the German Resuscitation Council <TextLink reference="28"></TextLink>. Unperformed actions were recorded as the number of errors (n).</Pgraph><SubHeadline2>2.3.5. SIMARENA trial schedule</SubHeadline2><Pgraph>The trial was divided into six phases (see figure 4 <ImgLink imgNo="4" imgType="figure" />). Following a five-minute baseline phase, during which the participant was instructed to sit quietly on a chair and relax, the pre-resuscitation phase with the initial questionnaires and the first saliva sample commenced. It was instructed that the participant would find an unconscious person in the SAM and would perform a bystander resuscitation with ventilation after verifying the need for it. The participants in the control group (CG) entered the SAM, which displayed a white background without a tone signal (see figure 5 <ImgLink imgNo="5" imgType="figure" />). Participants in the intervention group (IG) were shown a visual and auditory representation of a major road in the SAM (see figure 6 <ImgLink imgNo="6" imgType="figure" />). If the participant wanted to call emergency services or request an automated external defibrillator, the examiner took over these tasks using a standardized response list (see table 5 <ImgLink imgNo="5" imgType="table" />). After five minutes, the resuscitation phase ended, and during the post-resuscitation phase the next questionnaires were completed, and a second saliva sample was collected. After five minutes, the ten-minute &#8220;recovery&#8221; phase was initiated, during which the participant was instructed to relax while sitting. During the &#8220;rest&#8221; phase, the participant was presented the final questionnaires, and a final saliva sample was taken.</Pgraph><SubHeadline>2.4. Statistical analysis</SubHeadline><Pgraph>A priori power analysis was conducted using G&#42;Power 3: Statistical Power Analyses from Heinrich-Heine-University D&#252;sseldorf based on a study by Mills et al. on the effects of emergency medical high- and low-fidelity simulations on cardiac reactivity <TextLink reference="29"></TextLink>. To obtain statistically significant results regarding cardiac reactivity as the primary target of objective stress perception, a total sample of 38 participants would have been necessary based on these calculations. The participants were randomized into the intervention and control group using the RITA software (Randomization In Treatment Arms, StatSol, L&#252;beck) prior to the start of the trial. The statistical analysis was performed with the assistance of the Institute of Biometry and Medical Informatics using IBM SPSS Statistics 29 software (IBM, Ehningen, Germany). Descriptive analyses of the variables under investigation were conducted initially. The data was tested for normal distribution using the Shapiro-Wilk test. If the parameters were normally distributed, the Welch test was chosen as the metric test procedure. If the parameters did not follow a normal distribution, the Mann-Whitney U test was used as a non-parametric test. The distribution was tested using the Kolmogorov-Smirnov test for two samples after standardizing the data. The effect size was determined using Cohen&#8217;s d for metric methods and Pearson&#8217;s correlation coefficient r for non-metric methods.</Pgraph></TextBlock>
    <TextBlock name="2. Methoden" linked="yes" language="de">
      <MainHeadline>2. Methoden</MainHeadline><SubHeadline>2.1. Entwicklung</SubHeadline><Pgraph>Bei der Projektionsfl&#228;che der SAM handelt es sich um eine halbrunde gebogene 180&#176; Holzkonstruktion, die aus mehreren Segmenten besteht und mit vier Millimetern matter wei&#223;er Farbe beschichtet ist. Die Kurzdistanzbeamer und die Deckenhalterungen wurden so weit entfernt von der Projektionsfl&#228;che angebracht, dass durch beide Kurzdistanzbeamer alle Anteile der Projektionsfl&#228;che beleuchtet wurden (siehe Abbildung 1 <ImgLink imgNo="1" imgType="figure" /> und Abbildung 2 <ImgLink imgNo="2" imgType="figure" />). Um aus zwei eigenst&#228;ndigen Projektionen der Kurzdistanzbeamer eine gemeinsame Projektion zu erm&#246;glichen, wurden beide Kurzdistanzbeamer mittels der NVIDIA Systemsteuerung &#252;ber die Funktion &#8222;NVIDIA Surround&#8220; im Men&#252; &#8222;3D-Einstellungen&#8220; synchronisiert und zu einer einzigen Projektion vereint. Die Immersive Display Software erm&#246;glichte die Anpassung der Projektion an die Rundung und Ma&#223;e der Projektionsfl&#228;che (siehe Abbildung 3 <ImgLink imgNo="3" imgType="figure" />). F&#252;r die Panorama-Videoaufzeichnungen wurde die Nikon KeyMission 360 4K einen Meter &#252;ber dem Boden auf einem Stativ befestigt und eine f&#252;nfmin&#252;tige Aufnahme gestartet. Um das 360&#176;-Panoramavideo in ein 180&#176;-Panoramavideo umzuwandeln, wurde es mit dem Videobearbeitungsprogramm iMovie auf einen horizontalen Winkel von 180&#176; zugeschnitten. Bei Bedarf wurden den Videos zus&#228;tzliche T&#246;ne hinzugef&#252;gt. Die Videoaufnahmen k&#246;nnen mit dem QuickTime- oder VLC-Player an die Gr&#246;&#223;e der Projektionsfl&#228;che angepasst und abgespielt werden. Um einen farblich passenden Untergrund f&#252;r die Umgebungssimulation zu erm&#246;glichen, wurde au&#223;erdem ein dunkelgrauer Teppich verlegt, der auch das Knien der Teilnehmenden angenehmer machen soll. Au&#223;erdem wurde ein Ventilator zur Simulation von Wind, sowie eine Nebelmaschine und ein Lichtblitzstroboskop &#252;ber ein Funkschalt-Set in der Arena angeschlossen (siehe Tabelle 1 <ImgLink imgNo="1" imgType="table" />).</Pgraph><SubHeadline>2.2. Pilotstudie</SubHeadline><Pgraph>Um zu untersuchen, ob das Ziel einer realistischen Umgebungsdarstellung durch die SAM erreicht wird und ob die SAM einen Einfluss auf das Stressempfinden hat, wurde die SAM in einer Pilotstudie im Rahmen zweier Lehrveranstaltungen zur Polytrauma-Versorgung im Magdeburger Ausbildungszentrum f&#252;r Medizinische Basisfertigkeiten (MAMBA Skillslab) evaluiert. Zwei Simulationsszenarien wurden mit Umgebungsdarstellung durch die SAM und zwei Simulationsszenarien in realen, nicht durch die SAM dargestellten, Umgebungen durchgef&#252;hrt. In der SAM wurde eine Szene in einem Wald und eine Szene an einer stark befahrenen Stra&#223;e simuliert. Als echte Umgebung fungierten ein Treppenhaus und eine Stra&#223;e vor dem Ausbildungszentrum. In allen Simulationen mussten die Teilnehmenden eine Laerdal Resusci Anne QCPR-Ganzk&#246;rper mit Airwaykopf im Rahmen eines Polytraumaszenarios versorgen. Im Anschluss an die Szenarien wurde von allen Teilnehmenden ein Fragebogen mit acht Fragen in Form von Likert-Skalen ausgef&#252;llt (siehe Tabelle 2 <ImgLink imgNo="2" imgType="table" />). Drei Fragen wurden erst im zweiten Kurs hinzugef&#252;gt.</Pgraph><SubHeadline>2.3. SIMARENA-Studie</SubHeadline><SubHeadline2>2.3.1. Subjektives Stressempfinden</SubHeadline2><Pgraph>Eine visuelle Analogskala (VAS-S) von 0 mm (&#8222;kein Stress&#8220;) bis 100 mm (&#8222;maximaler Stress&#8220;) diente als prim&#228;rer Endpunkt des subjektiven Stressempfindens. Als sekund&#228;rer Endpunkt fungierte das State-Trait-Angst-Inventar (STAI), welches anhand von zwei Frageb&#246;gen zwischen aktueller Angst, die in ihrer Intensit&#228;t im Laufe der Zeit und in verschiedenen Situationen variiert (STAI-S), und habitueller Angst (STAI-T) unterscheidet <TextLink reference="18"></TextLink>. Die Fragb&#246;gen bestehen jeweils aus 20 Items auf einer vierstufigen Antwortskala. Die Werte der Items werden aufaddiert, wodurch sich zwei Gesamtpunktzahlen zwischen 20 und 80 ergeben <TextLink reference="18"></TextLink>. Die Faktoren &#8222;aktuelle Handlungsf&#228;higkeit&#8220; (BEA), &#8222;emotionale Spannung&#8220; (TEN), &#8222;emotionale Situationsbewertung&#8220; (STIM) und &#8222;Selbstkontrolle&#8220; (SPAN) der Eigenzustandsskala nach Nitsch (EZ) wurden als zus&#228;tzliche sekund&#228;re Endpunkte untersucht <TextLink reference="19"></TextLink>, <TextLink reference="20"></TextLink>. Die EZ besteht aus 40 Eigenschaftsw&#246;rtern, die auf einer 6-stufigen Ordinalskala von 1 &#8222;kaum&#8220; bis 6 &#8222;v&#246;llig&#8220; bewertet werden. Nach &#220;berf&#252;hrung der Item-Rohwerte in fl&#228;chentransformierte z&#8216;-Werte werden diese &#252;ber eine Aufsummierung und eine Stanine-Transformation zu 14 Bin&#228;rfaktoren in einer dreistufigen Hierarchie zusammengefasst <TextLink reference="19"></TextLink>, <TextLink reference="20"></TextLink>. Die Stanine-Skalen von eins bis neun sind so gepolt, dass bei allen Faktoren mit zunehmenden Werten die subjektiv positive Einsch&#228;tzung der eigenen Handlungslage zunimmt <TextLink reference="20"></TextLink>. Der Parameter &#8222;aktuelle Handlungsbereitschaft&#8220; (MOT) wurde verwendet, um die Motivationslage der Teilnehmenden vor der Studienintervention zu bestimmen <TextLink reference="20"></TextLink>.</Pgraph><SubHeadline2>2.3.2. Objektives Stressempfinden</SubHeadline2><Pgraph>Die kardiale Reaktivit&#228;t (CR), definiert als die Differenz zwischen der mittleren Herzfrequenz w&#228;hrend der Reanimations- und einer Baseline-Phase vor der Reanimation, wurde als prim&#228;rer Endpunkt des objektiven Stressempfindens verwendet. Zu diesem Zweck wurde eine kontinuierliche Elektrokardiographie mit dem Holter-EKG medilog AR12plus (SCHILLER Medizintechnik GmbH, Obfelden, Schweiz) durchgef&#252;hrt. Mithilfe der Software medilog DARWIN2 (SCHILLER Medizintechnik GmbH) wurde die elektrische Herzaktivit&#228;t &#252;ber drei Ableitungen automatisch erfasst, &#252;berpr&#252;ft und falsch erkannte Herzaktivit&#228;ten manuell korrigiert. Sekund&#228;re Endpunkte f&#252;r das objektive Stressempfinden waren die Herzfrequenz (HR) und folgende Parameter der Herzfrequenzvariabilit&#228;t (HRV) w&#228;hrend der Reanimation: SDNN (Standardabweichung der NN-Intervalle), SNS-Index (Sympathetic Nervous System Index), SI (Stress Index) und SD2 (Standardabweichung der Punktabst&#228;nde zum L&#228;ngsdurchmesser). Die HRV-Analyse erfolgte mithilfe der Software Kubios HRV Version 2.0 (Biosignal Analysis and Medical Imaging Group, Universit&#228;t Kuopio, Finnland). Die Atemfrequenz (RR) unmittelbar nach der Reanimation wurde ebenfalls als sekund&#228;rer Endpunkt untersucht und kontinuierlich mit dem Vernier Go Direct Respiratory Belt aufgezeichnet und mit der Software Vernier Graphical Analysis&#8482; 4 ausgewertet. Abschlie&#223;end wurde das Verh&#228;ltnis der Alpha-Amylase-Aktivit&#228;t im Speichel (sAA) unmittelbar nach der Reanimation zum Ruhewert vor der Reanimation als weitere sekund&#228;rer Endpunkt f&#252;r das objektive Stressempfinden herangezogen. Zu diesem Zweck wurden von den Teilnehmenden mittels Salivetten (SARSTEDT) drei Speichelproben aufgefangen. Die Teilnehmenden wurden angewiesen, die Saugrollen der Salivetten zwei Minuten lang in eine Wangentasche zu legen, ohne zu kauen oder zu sprechen <TextLink reference="21"></TextLink>, <TextLink reference="22"></TextLink>, <TextLink reference="23"></TextLink>. Nach einer Lagerung bei -20&#176;C f&#252;r maximal drei Tage wurden die Proben einer automatisierten maschinellen In-vitro-Testung mit dem Roche Cobas6000 zugef&#252;hrt <TextLink reference="23"></TextLink>, <TextLink reference="24"></TextLink>, <TextLink reference="25"></TextLink>. Dazu wurden die Proben bei Zimmertemperatur aufgetaut und zehn Minuten lang bei 4000 Umdrehungen pro Minute bei Raumtemperatur zentrifugiert. Es wurden 10 &#956;l der Probe mit 990 &#956;l Aqua destillata versetzt und nach Kalibrierung des Messsystems mit Aqua destillata und einer Standardl&#246;sung zur Kalibrierung von Roche die Messung mittels des c501 Moduls im Serum-Modus begonnen <TextLink reference="24"></TextLink>. Die Roche cobas c Systeme berechneten automatisch die Analytaktivit&#228;t der Probe <TextLink reference="24"></TextLink>. Der Umrechnungsfaktor betrug: U&#47;Lx0.0167&#61;&#956;kat&#47;L. Die kinetische Methode beruhte auf der Spaltung von 4,6-Ethyliden-(G7)-1,4-Nitrophenyl-(G1)-&#945;,D-maltoheptaosid (Ethylidene Protected Substrate&#61;EPS) durch die Alpha-Amylase und die nachfolgende Hydrolyse aller Spaltprodukte mit Hilfe der Alpha-Glucosidase (Hilfsenzym) zu p-Nitrophenol (100&#37; Chromophor-Freisetzung) <TextLink reference="24"></TextLink>. Die Farbintensit&#228;t des gebildeten p-Nitrophenols war direkt proportional zur Alpha-Amylase-Aktivit&#228;t und wurde durch Messung der Extinktionszunahme bestimmt <TextLink reference="24"></TextLink>.</Pgraph><SubHeadline2>2.3.3. Subjektive Reanimationsqualit&#228;t</SubHeadline2><Pgraph>Als prim&#228;rer Endpunkt der subjektiven Reanimationsqualit&#228;t wurde eine visuelle Analogskala von 0 mm (&#8222;schlechte Reanimation&#8220;) bis 100 mm (&#8222;ausgezeichnete Reanimation&#8220;) gew&#228;hlt, welche von den Teilnehmenden unmittelbar nach der Reanimation ausgef&#252;llt wurde.</Pgraph><SubHeadline2>2.3.4. Objektive Reanimationsqualit&#228;t</SubHeadline2><Pgraph>Der prim&#228;re Endpunkt der objektiven Reanimationsqualit&#228;t war der TOTAL-Score (TOTAL), welcher unmittelbar nach der Reanimation von der Laerdal Resusci Anne QCPR und dem Laerdal SimPad PLUS SkillReporter als Gesamtwert f&#252;r die Reanimationsleistung auf Grundlage der Parameter Kompression, Beatmung und Zeit mit CPR-Aktivit&#228;t berechnet wurde <TextLink reference="26"></TextLink>. Der verwendete Algorithmus wurde von Laerdal Medical in enger Zusammenarbeit mit Mitgliedern des Emergency Cardiovascular Care (ECC) Unterausschusses der American Heart Association (AHA) und Co-Autoren der AHA-Leitlinie f&#252;r die Herz-Lungen-Wiederbelebung erstellt <TextLink reference="27"></TextLink>. Dar&#252;ber hinaus wurden mehrere Reanimationsparameter als sekund&#228;re Endpunkte gemessen (siehe Tabelle 3 <ImgLink imgNo="3" imgType="table" />) <TextLink reference="26"></TextLink>. Als weiterer sekund&#228;rer Endpunkt wurde die Checkliste Laienreanimation definiert (siehe Tabelle 4 <ImgLink imgNo="4" imgType="table" />). Diese Checkliste wurde vom Versuchsleiter w&#228;hrend der Reanimation ausgef&#252;llt und orientierte sich an den Empfehlungen f&#252;r die Laienreanimation (&#8222;BLS-Ablauf bei Erwachsenen&#8220;) der Leitlinie von 2015 des Deutschen Rates f&#252;r Wiederbelebung <TextLink reference="28"></TextLink>. Nicht durchgef&#252;hrte Handlungen wurden als Fehleranzahl festgehalten.</Pgraph><SubHeadline2>2.3.5. Ablaufplan SIMARENA-Studie</SubHeadline2><Pgraph>Die Studie war in sechs Phasen unterteilt (siehe Abbildung 4 <ImgLink imgNo="4" imgType="figure" />). Nach einer f&#252;nfmin&#252;tigen Baseline-Phase, in der die Teilnehmenden angewiesen wurden, ruhig auf einem Stuhl zu sitzen und sich zu entspannen, begann die Pr&#228;-Reanimations-Phase mit den ersten Frageb&#246;gen und der ersten Speichelprobe. Die Teilnehmenden wurden instruiert, eine bewusstlose Person in der SAM vorzufinden und nach &#220;berpr&#252;fung der Notwendigkeit eine Laienreanimation mit Beatmung durchzuf&#252;hren. Die Teilnehmenden der Kontrollgruppe (KG) betraten die SAM, welche einen wei&#223;en Hintergrund ohne Tonsignal darstellte (siehe Abbildung 5 <ImgLink imgNo="5" imgType="figure" />). Den Teilnehmenden der Interventionsgruppe (IG) wurde eine visuelle und akustische Darstellung einer Hauptverkehrsstra&#223;e in der SAM geboten (siehe Abbildung 6 <ImgLink imgNo="6" imgType="figure" />). Wenn die Teilnehmenden den Rettungsdienst rufen oder einen automatisierten externen Defibrillator anfordern wollten, &#252;bernahm der Versuchsleiter diese Aufgaben anhand einer standardisierten Antwortliste (siehe Tabelle 5 <ImgLink imgNo="5" imgType="table" />). Nach f&#252;nf Minuten endete die Reanimationsphase und in der Post-Reanimationsphase wurden die n&#228;chsten Frageb&#246;gen ausgef&#252;llt und eine zweite Speichelprobe entnommen. Nach f&#252;nf Minuten begann die zehnmin&#252;tige Erholungsphase, in welcher die Teilnehmenden angewiesen wurden, sich im Sitzen zu entspannen. W&#228;hrend der Ruhephase wurden den Teilnehmern die abschlie&#223;enden Frageb&#246;gen vorgelegt und eine letzte Speichelprobe entnommen.</Pgraph><SubHeadline>2.4. Statistik</SubHeadline><Pgraph>Eine a priori Power-Analyse wurde mit dem Programm G&#42;Power 3: Statistical Power Analyses der Heinrich-Heine-Universit&#228;t D&#252;sseldorf auf Basis einer Studie von Mills et al. zu den Auswirkungen von notfallmedizinischen Simulationen mit hoher und niedriger Realit&#228;tsn&#228;he auf die kardiale Reaktivit&#228;t durchgef&#252;hrt <TextLink reference="29"></TextLink>. Um statistisch signifikante Ergebnisse hinsichtlich der kardialen Reaktivit&#228;t als prim&#228;ren Endpunkt des objektiven Stressempfindens zu erhalten, w&#228;re nach diesen Berechnungen eine Gesamtstichprobe von 38 Teilnehmenden erforderlich gewesen. Die Teilnehmenden wurden vor Beginn der Studie mit Hilfe der Software RITA (Randomization In Treatment Arms, StatSol, L&#252;beck) in eine Interventions- und eine Kontrollgruppe randomisiert. Die statistische Auswertung erfolgte mit Unterst&#252;tzung des Instituts f&#252;r Biometrie und Medizinische Informatik unter Verwendung der Software IBM SPSS Statistics 29 (IBM, Ehningen, Deutschland). Zun&#228;chst wurden deskriptive Analysen der Untersuchungsgr&#246;&#223;en durchgef&#252;hrt. Die &#220;berpr&#252;fung der Daten auf Normalverteilung erfolgt mittels des Shapiro-Wilk-Tests. Wiesen die Parameter eine Normalverteilung auf, wurde sich f&#252;r die Durchf&#252;hrung des Welch-Tests als metrisches Testverfahrens entschieden. Wiesen die Parameter keine Normalverteilung auf, wurde der Mann-Whitney-U-Test als nichtmetrisches Testverfahren genutzt. Die Verteilung wurde nach Standardisierung der Daten mit dem Kolmogorov-Smirnov-Test f&#252;r zwei Stichproben gepr&#252;ft. Die Effektst&#228;rke wurde nach metrischen Verfahren mittels Cohen&#8217;s d und bei nicht-metrischen Verfahren mittels des Pearson Korrelationskoeffizienten r bestimmt. </Pgraph></TextBlock>
    <TextBlock name="3. Results" linked="yes" language="en">
      <MainHeadline>3. Results</MainHeadline><SubHeadline>3.1. Pilot study</SubHeadline><Pgraph>The SAM was constructed with development costs of 7,726.50 euros (see table 1 <ImgLink imgNo="1" imgType="table" />). All 38 participants completed the questionnaire in the survey. Most of the participants were third to fifth year students.  The results of the survey demonstrate that the SAM contributed to the perception of a realistic environment through the video projection, ambient noise, and the props utilized. The video projections were predominantly perceived with peripheral vision, and subjective stress was reported during the simulations in the SAM (see table 2 <ImgLink imgNo="2" imgType="table" />).</Pgraph><SubHeadline>3.2. SIMARENA trial</SubHeadline><Pgraph>The SIMARENA trial involved 46 medical students in the clinical part of the study. 21 students were randomized to the intervention group (IG) and 25 to the control group (CG). Apart from the gender distribution, there were no significant group differences. More women than men were randomized to the intervention group (IG: 61.9&#37;, CG: 44.0&#37;) (see table 6 <ImgLink imgNo="6" imgType="table" />). A total of five HR (IG: 3, CG: 2) and six RR (IG: 3, CG: 3) recordings were excluded from the final analysis due to technical disturbances during the examinations or more than one percent of extrasystoles on the ECG <TextLink reference="30"></TextLink>, <TextLink reference="31"></TextLink>. </Pgraph><Pgraph>The post-resuscitation VAS-S, as the primary outcome measure of subjective stress, showed a significant difference between IG and CG (see figure 7 <ImgLink imgNo="7" imgType="figure" />). Also, the EZ parameters BEA, TEN, STIM and SPAN of the post resuscitation as secondary outcome measures showed significant differences between IG and CG. The secondary outcome measure STAI-S for post-resuscitation showed no significant difference between IG and CG (see table 7 <ImgLink imgNo="7" imgType="table" />). Cardiac reactivity, as the primary outcome measure of objective stress perception, showed a statistically significant difference between IG and CG (see figure 8 <ImgLink imgNo="8" imgType="figure" />). The HR and HRV parameters SDNN, SNS, SI, and SD2, as well as the RR difference between the post-resuscitation- and baseline-phase and the RR of the post-resuscitation phase, also showed significant differences between IG and CG as secondary endpoints. The sAA ratio did not show a statistically significant difference between the IG and the CG (see table 8 <ImgLink imgNo="8" imgType="table" />). The VAS-R as the primary outcome measure of subjective quality of resuscitation and the TOTAL score as the primary outcome measure of objective resuscitation quality showed no significant difference between IG and CG (see table 3 <ImgLink imgNo="3" imgType="table" /> and table 9 <ImgLink imgNo="9" imgType="table" />). The other resuscitation parameters also showed no significant differences, except for compressions with correct hand position and the number of errors according to the resuscitation checklist (see table 3 <ImgLink imgNo="3" imgType="table" /> and figure 9 <ImgLink imgNo="9" imgType="figure" />).</Pgraph></TextBlock>
    <TextBlock name="3. Ergebnisse" linked="yes" language="de">
      <MainHeadline>3. Ergebnisse</MainHeadline><SubHeadline>3.1. Pilotstudie</SubHeadline><Pgraph>Die SAM wurde mit Entwicklungskosten von 7.726,50 Euro konstruiert (siehe Tabelle 1 <ImgLink imgNo="1" imgType="table" />). Alle 38 Teilnehmenden haben den Fragebogen der Umfrage ausgef&#252;llt. Die meisten Teilnehmenden waren Medizinstudierende des dritten bis f&#252;nften Studienjahres. Die Ergebnisse der Umfrage zeigen, dass die SAM durch die Videoprojektion, die Umgebungsger&#228;usche und die verwendeten Requisiten zu einer realistischen Wahrnehmung der Umgebung beigetragen hat. Die Videoprojektionen wurden &#252;berwiegend mit dem peripheren Sehen wahrgenommen und w&#228;hrend der Simulationen in der SAM wurde von den Teilnehmenden von subjektivem Stressempfinden berichtet (siehe Tabelle 2 <ImgLink imgNo="2" imgType="table" />).</Pgraph><SubHeadline>3.2. SIMARENA-Studie</SubHeadline><Pgraph>An der SIMARENA-Studie nahmen 46 Medizinstudierende des klinischen Studienabschnittes teil. 21 Studierende wurden in die Interventions- (IG) und 25 in die Kontrollgruppe (KG) randomisiert. Abgesehen von der Geschlechterverteilung gab es keine signifikanten Gruppenunterschiede. Es wurden mehr Frauen als M&#228;nner der Interventionsgruppe zugeordnet (IG: 61,9&#37;, KG: 44,0&#37;, siehe Tabelle 6 <ImgLink imgNo="6" imgType="table" />). Aufgrund technischer St&#246;rungen w&#228;hrend der Untersuchungen oder mehr als einem Prozent an Extrasystolen im EKG wurden insgesamt f&#252;nf HR- (IG: 3, KG: 2) und sechs RR-Aufzeichnungen (IG: 3, KG: 3) aus der Endauswertung ausgeschlossen <TextLink reference="30"></TextLink>, <TextLink reference="31"></TextLink>. Die VAS-S der Post-Reanimation als prim&#228;rer Endpunkt des subjektiven Stressempfindens zeigte einen signifikanten Unterschied zwischen der IG und KG (siehe Abbildung 7 <ImgLink imgNo="7" imgType="figure" />). Auch die EZ-Parameter BEA, TEN, STIM und SPAN der Post-Reanimation als sekund&#228;re Endpunkte des subjektiven Stressempfindens zeigten signifikante Unterschiede zwischen der IG und KG. Der sekund&#228;re Endpunkt STAI-S der Post-Reanimation zeigte keinen signifikanten Unterschied zwischen der IG und KG (siehe Tabelle 7 <ImgLink imgNo="7" imgType="table" />). Die kardiale Reaktivit&#228;t als prim&#228;rer Endpunkt f&#252;r das objektive Stressempfinden zeigte einen statistisch signifikanten Unterschied zwischen der IG und KG (siehe Abbildung 8 <ImgLink imgNo="8" imgType="figure" />). Die HR und HRV-Parameter SDNN, SNS, SI und SD2 sowie die RR-Differenz zwischen der Post-Reanimations- und der Baseline-Phase sowie die RR der Post-Reanimations-Phase zeigten als sekund&#228;re Endpunkte ebenfalls signifikante Unterschiede zwischen der IG und KG. Das sAA-Verh&#228;ltnis zeigte keinen statistisch signifikanten Unterschied zwischen der IG und der KG (siehe Tabelle 8 <ImgLink imgNo="8" imgType="table" />). Die VAS-R als prim&#228;rer Endpunkt der subjektiven Reanimationsqualit&#228;t und der TOTAL-Score als prim&#228;rer Endpunkt f&#252;r die objektive Reanimationsqualit&#228;t zeigten keinen signifikanten Unterschied zwischen der IG und KG (siehe Tabelle 3 <ImgLink imgNo="3" imgType="table" /> und Tabelle 9 <ImgLink imgNo="9" imgType="table" />). Die anderen Reanimationsparameter zeigten ebenfalls keine signifikanten Unterschiede, mit Ausnahme der Kompressionen mit korrekter Handposition und der Fehleranzahl nach Reanimations-Checkliste (siehe Tabelle 3 <ImgLink imgNo="3" imgType="table" /> und Abbildung 9 <ImgLink imgNo="9" imgType="figure" />).</Pgraph></TextBlock>
    <TextBlock name="4. Discussion" linked="yes" language="en">
      <MainHeadline>4. Discussion</MainHeadline><SubHeadline>4.1. Development of the SAM</SubHeadline><Pgraph>With a development cost of 7,726.50 euros the SAM is the first low-cost simulation arena in Germany <TextLink reference="7"></TextLink>, <TextLink reference="8"></TextLink>. However, due to the lower expenditure, the quality of the video recordings, video projections and ambient sounds will be lower <TextLink reference="1"></TextLink>, <TextLink reference="2"></TextLink>, <TextLink reference="3"></TextLink>, <TextLink reference="5"></TextLink>, <TextLink reference="6"></TextLink>, <TextLink reference="7"></TextLink>. The diameter of the SAM is also slightly smaller than the diameter of comparable simulation arenas due to the spatial conditions  <TextLink reference="1"></TextLink>, <TextLink reference="5"></TextLink>, <TextLink reference="6"></TextLink>, <TextLink reference="7"></TextLink>, <TextLink reference="8"></TextLink>, <TextLink reference="10"></TextLink>. To provide enough space for the simulation, the SAM has a 180&#176; projection screen instead of a 270&#176; projection screen <TextLink reference="1"></TextLink>, <TextLink reference="3"></TextLink>, <TextLink reference="4"></TextLink>, <TextLink reference="5"></TextLink>, <TextLink reference="7"></TextLink>. In the future, the quality of the environmental presentation could be further enhanced by using several parallel cameras to record the environment, a larger number of short-distance projectors, or several LCD monitors surrounding the simulation arena as screens, as well as stereoscopic three-dimensional projections. The integration of surround sound systems and scent generators has the potential to further enhance the immersive simulation experience. However, research into this topic is still pending <TextLink reference="1"></TextLink>, <TextLink reference="2"></TextLink>, <TextLink reference="3"></TextLink>, <TextLink reference="4"></TextLink>, <TextLink reference="5"></TextLink>, <TextLink reference="6"></TextLink>, <TextLink reference="7"></TextLink>, <TextLink reference="8"></TextLink>, <TextLink reference="9"></TextLink>, <TextLink reference="10"></TextLink>, <TextLink reference="13"></TextLink>, <TextLink reference="32"></TextLink>. Unlike the arenas in M&#252;nster and Essen, developed with external partners, the SAM was built in-house and lacks an external technical contact <TextLink reference="1"></TextLink>, <TextLink reference="2"></TextLink>, <TextLink reference="5"></TextLink>, <TextLink reference="6"></TextLink>. In the event that difficulties arise in adjusting the image to the SAM screen, assistance can be obtained by contacting the company Fly Elise-ng. Since its development, SAM has been utilized regularly for curricular and optional emergency medicine courses at Otto-von-Guericke University Magdeburg and Magdeburg University Hospital.</Pgraph><SubHeadline>4.2. Pilot study</SubHeadline><Pgraph>The survey results show a high level of student satisfaction with the SAM, that is also reflected in the ratings of comparable simulation arenas <TextLink reference="7"></TextLink>, <TextLink reference="8"></TextLink>, <TextLink reference="9"></TextLink>, <TextLink reference="13"></TextLink>. The results of the survey also suggest that the SAM contributed to the perception of a realistic environment and stress. This is also described in other studies <TextLink reference="7"></TextLink>, <TextLink reference="8"></TextLink>, <TextLink reference="9"></TextLink>, <TextLink reference="13"></TextLink>. Our hypothesis that the SAM would provide a satisfactory and realistic representation of the environment could thus be confirmed.</Pgraph><SubHeadline>4.3. SIMARENA trial</SubHeadline><SubHeadline2>4.3.1. Subjective perception of stress</SubHeadline2><Pgraph>The significantly higher VAS-S values in the IG immediately after resuscitation suggests that the SAM&#39;s depiction of the environment contributes to an increase in subjective stress, an effect that has also been reported in comparable studies <TextLink reference="7"></TextLink>, <TextLink reference="9"></TextLink>, <TextLink reference="13"></TextLink>. The significantly reduced parameters BEA, TEN, STIM, and SPAN of the EZ support this result. In contrast, the STAI-S showed no significant difference between IG and CG. In the literature, comparisons between high- and low-fidelity simulations often do not show significant differences in the STAI-S <TextLink reference="17"></TextLink>, <TextLink reference="33"></TextLink>. In some studies, a significant increase in STAI-S was shown when additional stress was induced not through changes in virtual environmental conditions, but through changes in the behavior of actors or the perceived threat of injuries <TextLink reference="34"></TextLink>, <TextLink reference="35"></TextLink>, <TextLink reference="36"></TextLink>. Our hypothesis that the subjective stress level of medical students increases more during a 5-minute lay resuscitation with SAM than without SAM could thus be confirmed.</Pgraph><SubHeadline2>4.3.2. Objective perception of stress</SubHeadline2><Pgraph>The significant increase in CR as the primary target of objective stress perception suggests that SAM also objectively contributes to increasing stress perception. A significantly increased CR and HR can also be found in the literature <TextLink reference="29"></TextLink>, <TextLink reference="34"></TextLink>. The significant changes in HRV and the significant increase in respiratory rate as secondary endpoints confirm this result. Tramer et al. have previously demonstrated a significant reduction in SDNN during psychological stress during resuscitation efforts <TextLink reference="37"></TextLink>. It is imperative to acknowledge the disparity in gender distribution between the intervention and control group, as women generally exhibit higher heart rates compared to men. However, studies on HRV parameters have yielded contradictory results. Some studies have observed increased parasympathetic activity in women compared to men, while others have found increased sympathetic baseline activity in women <TextLink reference="30"></TextLink>, <TextLink reference="31"></TextLink>. The ratio of sAA from pre- to post-resuscitation phase did not show a significant increase between the IG and CG. While some studies report similar results, others have found significant increases in sAA <TextLink reference="22"></TextLink>, <TextLink reference="25"></TextLink>, <TextLink reference="38"></TextLink>, <TextLink reference="39"></TextLink>, <TextLink reference="40"></TextLink>. Due to large differences in mean values as well as partly negative results, however, a large interindividual variation in sAA must be assumed <TextLink reference="21"></TextLink>, <TextLink reference="22"></TextLink>, <TextLink reference="38"></TextLink>. The sAA measurements may also have been influenced by physical exertion during resuscitation or the circadian rhythm of sAA <TextLink reference="38"></TextLink>, <TextLink reference="41"></TextLink>, <TextLink reference="42"></TextLink>. Furthermore, it should be noted that there are different approaches in the literature regarding the storage and processing of saliva samples <TextLink reference="21"></TextLink>, <TextLink reference="22"></TextLink>, <TextLink reference="23"></TextLink>, <TextLink reference="38"></TextLink>, <TextLink reference="40"></TextLink>. In summary, our hypothesis that the objective stress level of medical students increases more during a 5-minute lay resuscitation with SAM than without SAM was confirmed.</Pgraph><SubHeadline2>4.3.3. Quality of the resuscitation</SubHeadline2><Pgraph>Given that the TOTAL-Score, VAS-R, and secondary endpoints did not demonstrate a statistically significant difference between the IG and CG, our hypothesis that the subjective and objective resuscitation quality of medical students decreases more during a 5-minute lay resuscitation with SAM than without SAM could therefore not be confirmed. However, the literature suggests that the quality of care deteriorates due to increased stress levels during simulations <TextLink reference="9"></TextLink>, <TextLink reference="13"></TextLink>, <TextLink reference="17"></TextLink>. This discrepancy, with apparently increased subjective and objective stress levels in the IG without a corresponding reduction in resuscitation quality, can possibly be explained by the Yerkes-Dodson theory. The CG may have experienced the simulation without SAM in a state of understimulation with the same subjective and objective resuscitation quality as the IG, which was already in an incipient state of overstimulation on the Yerkes-Dodson curve due to the use of SAM (see figure 10 <ImgLink imgNo="10" imgType="figure" />) <TextLink reference="43"></TextLink>. The statistically significant reduction in compressions with correct hand position and the significantly increased mistakes in the IG as secondary outcome measures could be first indications of a reduced resuscitation quality in the context of the increased stress perception caused by the SAM. However, Wier et al. also demonstrated that aspects of team communication, team performance, and leadership were significantly reduced through simulation in simulation arenas, which were not investigated in the SIMARENA trial <TextLink reference="9"></TextLink>.</Pgraph><SubHeadline2>4.3.4. Limitations</SubHeadline2><Pgraph>The significance of the results of the pilot study could have been increased by selecting comparable environments for the SAM environment representation and the real environments. Ultimately, the pilot study was only intended to answer whether the SAM subjectively generates a high level of satisfaction among the participants, whether a realistic environment can be represented and whether a simulation in the SAM induces stress. It should also be noted that the pilot study and the SIMARENA trial were not blinded. Overall, only a few students with varying levels of training voluntarily participated in the studies, indicating a high degree of preselection. Therefore, the results cannot be generalized to emergency medical personnel. Other video projections, changes in ambient noise, as well as the use of props, wind, and fog could have altered the stress perception and quality of resuscitation. Overall, the studies compare simulations without an additional environment representation with simulations with an environment representation using the SAM. This approach was chosen because it allows the additional benefit of a simulation arena to be investigated. </Pgraph></TextBlock>
    <TextBlock name="4. Diskussion" linked="yes" language="de">
      <MainHeadline>4. Diskussion</MainHeadline><SubHeadline>4.1. Entwicklung der SAM</SubHeadline><Pgraph>Mit Entwicklungskosten von 7.726,50 Euro ist die SAM die erste kosteng&#252;nstige Simulationsarena in Deutschland <TextLink reference="7"></TextLink>, <TextLink reference="8"></TextLink>. Aufgrund der geringeren Ausgaben ist die Qualit&#228;t der Videoaufnahmen, Videoprojektionen und Umgebungsger&#228;usche jedoch geringer als in vergleichbaren Simulationsarenen <TextLink reference="1"></TextLink>, <TextLink reference="2"></TextLink>, <TextLink reference="3"></TextLink>. Der Durchmesser der SAM ist aufgrund der r&#228;umlichen Gegebenheiten ebenfalls etwas kleiner als der Durchmesser vergleichbarer Simulationsarenen <TextLink reference="1"></TextLink>, <TextLink reference="5"></TextLink>, <TextLink reference="6"></TextLink>, <TextLink reference="7"></TextLink>, <TextLink reference="8"></TextLink>, <TextLink reference="10"></TextLink>. Um gen&#252;gend Platz f&#252;r die Simulation zu bieten, verf&#252;gt die SAM &#252;ber eine 180&#176;-Projektionsfl&#228;che anstelle einer 270&#176;-Projektionsfl&#228;che <TextLink reference="1"></TextLink>, <TextLink reference="3"></TextLink>, <TextLink reference="4"></TextLink>, <TextLink reference="5"></TextLink>, <TextLink reference="7"></TextLink>. In Zukunft k&#246;nnte die Qualit&#228;t der Umgebungsdarstellung durch den Einsatz mehrerer paralleler Kameras zur Umgebungsaufzeichnung, einer gr&#246;&#223;eren Anzahl an Kurzdistanzbeamern oder mehrerer LCD-Monitore, die die Simulationsarena als Bildschirme umgeben, sowie durch stereoskopische dreidimensionale Projektionen weiter verbessert werden. Die Integration von Surround-Sound-Systemen und Duftgeneratoren hat ebenfalls das Potenzial, das immersive Simulationserlebnis weiter zu verst&#228;rken. Zu diesem Thema besteht weiterer Forschungsbedarf <TextLink reference="1"></TextLink>, <TextLink reference="2"></TextLink>, <TextLink reference="3"></TextLink>, <TextLink reference="4"></TextLink>, <TextLink reference="5"></TextLink>, <TextLink reference="6"></TextLink>, <TextLink reference="7"></TextLink>, <TextLink reference="8"></TextLink>, <TextLink reference="9"></TextLink>, <TextLink reference="10"></TextLink>, <TextLink reference="13"></TextLink>, <TextLink reference="32"></TextLink>. Im Gegensatz zu den Simulationsarenen in M&#252;nster und Essen, die mit externen Partnern entwickelt wurden, wurde die SAM in Eigenregie gebaut und verf&#252;gt &#252;ber keinen externen technischen Ansprechpartner <TextLink reference="1"></TextLink>, <TextLink reference="2"></TextLink>, <TextLink reference="5"></TextLink>, <TextLink reference="6"></TextLink>. Sollten Schwierigkeiten bei der Anpassung der Videoprojektionen an die gebogene Leinwand auftreten, kann Unterst&#252;tzung bei der Firma Fly Elise-ng angefragt werden. Die SAM wird regelm&#228;&#223;ig f&#252;r curriculare und fakultative Lehrveranstaltungen im Bereich der Notfallmedizin an der Otto-von-Guericke-Universit&#228;t Magdeburg und am Universit&#228;tsklinikum Magdeburg eingesetzt.</Pgraph><SubHeadline>4.2. Pilotstudie</SubHeadline><Pgraph>Die Umfrageergebnisse zeigen eine hohe Zufriedenheit der Studierenden mit der SAM, die sich auch in den Bewertungen vergleichbarer Simulationsarenen widerspiegelt <TextLink reference="7"></TextLink>, <TextLink reference="8"></TextLink>, <TextLink reference="9"></TextLink>, <TextLink reference="13"></TextLink>. Die Ergebnisse der Umfrage deuten auch darauf hin, dass der Einsatz der SAM zur Wahrnehmung einer realistischen Umgebung und von Stress beigetragen hat. Dies wird auch in anderen Studien beschrieben <TextLink reference="7"></TextLink>, <TextLink reference="8"></TextLink>, <TextLink reference="9"></TextLink>, <TextLink reference="13"></TextLink>. Unsere Hypothese, dass die SAM eine zufriedenstellende und realistische Umgebungsdarstellung liefern w&#252;rde, konnte somit angenommen werden.</Pgraph><SubHeadline>4.3. SIMARENA-Studie</SubHeadline><SubHeadline2>4.3.1. Subjektives Stressempfinden</SubHeadline2><Pgraph>Die signifikant h&#246;heren VAS-S-Werte in der IG unmittelbar nach der Reanimation lassen vermuten, dass die Umgebungsdarstellung durch die SAM zu einer Zunahme des subjektiven Stressempfindens beitr&#228;gt. Dieser Effekt wurde auch bereits in vergleichbaren Studien berichtet <TextLink reference="7"></TextLink>, <TextLink reference="9"></TextLink>, <TextLink reference="13"></TextLink>. Die deutlich reduzierten Parameter BEA, TEN, STIM und SPAN der EZ st&#252;tzen dieses Ergebnis. Im Gegensatz dazu zeigte das STAI-S keinen signifikanten Unterschied zwischen der IG und KG. In der Literatur zeigen Vergleiche zwischen Simulationen mit hoher und niedriger Realit&#228;tsn&#228;he oft keine signifikanten Unterschiede des STAI-S <TextLink reference="17"></TextLink>, <TextLink reference="33"></TextLink>. In einigen Studien wurde ein signifikanter Anstieg des STAI-S festgestellt, wenn zus&#228;tzlicher Stress nicht durch Ver&#228;nderungen der virtuellen Umgebungsbedingungen, sondern durch Ver&#228;nderungen im Verhalten der Darsteller oder die wahrgenommene Gefahr von Verletzungen hervorgerufen wurde <TextLink reference="34"></TextLink>, <TextLink reference="35"></TextLink>, <TextLink reference="36"></TextLink>. Unsere Hypothese, dass das subjektive Stressempfinden von Medizinstudierenden w&#228;hrend einer f&#252;nfmin&#252;tigen Laienreanimation mit Einsatz der SAM st&#228;rker ansteigt als ohne Einsatz der SAM, konnte somit best&#228;tigt werden.</Pgraph><SubHeadline2>4.3.2. Objektives Stressempfinden</SubHeadline2><Pgraph>Der signifikante Anstieg der CR als prim&#228;rer Endpunkt des objektiven Stressempfindens deutet darauf hin, dass die SAM auch objektiv zur Erh&#246;hung des Stressempfindens beitr&#228;gt. In der Literatur finden sich ebenfalls signifikant erh&#246;hte CR- und HR-Werte <TextLink reference="29"></TextLink>, <TextLink reference="34"></TextLink>. Die signifikanten Ver&#228;nderungen der HRV und der signifikante Anstieg der Atemfrequenz als sekund&#228;re Endpunkte best&#228;tigen dieses Ergebnis. Tramer et al. haben in der Vergangenheit bereits eine signifikante Verringerung der SDNN w&#228;hrend psychischem Stress bei Wiederbelebungsma&#223;nahmen gezeigt <TextLink reference="37"></TextLink>. Es ist unbedingt zu ber&#252;cksichtigen, dass die Geschlechterverteilung in der Interventions- und Kontrollgruppe unterschiedlich ist, da Frauen im Allgemeinen eine h&#246;here Herzfrequenz aufweisen als M&#228;nner. Studien zu HRV-Parametern haben jedoch widerspr&#252;chliche Ergebnisse geliefert. Einige Studien haben bei Frauen eine erh&#246;hte parasympathische Aktivit&#228;t im Vergleich zu M&#228;nnern beobachtet, w&#228;hrend andere eine erh&#246;hte sympathische Grundaktivit&#228;t bei Frauen festgestellt haben <TextLink reference="30"></TextLink>, <TextLink reference="31"></TextLink>. Das Verh&#228;ltnis der sAA von der Post- zur Pr&#228;-Reanimations-Phase zeigte keinen signifikanten Anstieg zwischen der IG und der KG. W&#228;hrend einige Studien &#228;hnliche Ergebnisse aufzeigen, konnten andere einen signifikanten Anstieg der sAA feststellen <TextLink reference="22"></TextLink>, <TextLink reference="25"></TextLink>, <TextLink reference="38"></TextLink>, <TextLink reference="39"></TextLink>, <TextLink reference="40"></TextLink>. Aufgrund gro&#223;er Unterschiede in den Mittelwerten sowie teilweise negativer Ergebnisse muss jedoch von einer gro&#223;en interindividuellen Streubreite der sAA ausgegangen werden <TextLink reference="21"></TextLink>, <TextLink reference="22"></TextLink>, <TextLink reference="38"></TextLink>. Die sAA-Messungen k&#246;nnten auch durch die k&#246;rperliche Anstrengung w&#228;hrend der Reanimation oder den zirkadianen Rhythmus der sAA beeinflusst worden sein <TextLink reference="38"></TextLink>, <TextLink reference="41"></TextLink>, <TextLink reference="42"></TextLink>. Dar&#252;ber hinaus ist zu beachten, dass in der Literatur unterschiedliche Ans&#228;tze hinsichtlich der Lagerung und Verarbeitung der Speichelproben bestehen <TextLink reference="21"></TextLink>, <TextLink reference="22"></TextLink>, <TextLink reference="23"></TextLink>, <TextLink reference="38"></TextLink>, <TextLink reference="40"></TextLink>. Zusammenfassend l&#228;sst sich sagen, dass die Hypothese, dass das objektive Stressempfinden von Medizinstudierenden w&#228;hrend einer f&#252;nfmin&#252;tigen Laienreanimation mit Einsatz der SAM st&#228;rker ansteigt als ohne Einsatz der SAM, angenommen werden kann.</Pgraph><SubHeadline2>4.3.3. Reanimationsqualit&#228;t</SubHeadline2><Pgraph>Da der TOTAL-Score, die VAS-R und die sekund&#228;ren Endpunkte keinen statistisch signifikanten Unterschied zwischen der IG und der KG zeigten, konnte unsere Hypothese, dass die subjektive und objektive Reanimationsqualit&#228;t von Medizinstudierenden w&#228;hrend einer f&#252;nfmin&#252;tigen Laienreanimation mit Einsatz der SAM st&#228;rker abnimmt als ohne Einsatz der SAM, nicht best&#228;tigt werden. Die Literatur deutet jedoch darauf hin, dass sich die Versorgungsqualit&#228;t aufgrund eines erh&#246;hten Stressniveaus w&#228;hrend Simulationen verschlechtert <TextLink reference="9"></TextLink>, <TextLink reference="13"></TextLink>, <TextLink reference="17"></TextLink>. Diese Diskrepanz, bei der offenbar das subjektive und objektive Stressempfinden in der IG erh&#246;ht waren, ohne dass dies mit einer entsprechenden Verringerung der Reanimationsqualit&#228;t einherging, l&#228;sst sich m&#246;glicherweise durch die Yerkes-Dodson-Theorie erkl&#228;ren. Die KG hat die Simulation ohne Einsatz der SAM m&#246;glicherweise in einem Zustand der Unterstimulation mit Erreichen derselben subjektiven und objektiven Reanimationsqualit&#228;t erlebt wie die IG, welche sich aufgrund des Einsatzes der SAM bereits in einem beginnenden Zustand der &#220;berstimulation auf der Yerkes-Dodson-Kurve befand (siehe Abbildung 10 <ImgLink imgNo="10" imgType="figure" />) <TextLink reference="43"></TextLink>. Die statistisch signifikante Verringerung der Kompressionen mit korrekter Handposition und die signifikant erh&#246;hte Fehlerquote in der IG als sekund&#228;re Endpunkte k&#246;nnten erste Anzeichen f&#252;r eine verminderte Reanimationsqualit&#228;t im Zusammenhang mit dem durch die SAM verursachten erh&#246;hten Stressempfinden sein. Wier et al. zeigten jedoch auch, dass Aspekte der Teamkommunikation, der Teamleistung und der F&#252;hrung, welche in der SIMARENA-Studie nicht untersucht wurden, durch Simulationen in Simulationsarenen ma&#223;geblich beeintr&#228;chtigt werden <TextLink reference="9"></TextLink>.</Pgraph><SubHeadline2>4.3.4. Limitationen</SubHeadline2><Pgraph>Die Aussagekraft der Ergebnisse der Pilotstudie h&#228;tte durch die Auswahl vergleichbarer Umgebungen f&#252;r die Umgebungsdarstellung durch die SAM und die realen Umgebungen erh&#246;ht werden k&#246;nnen. Letztendlich sollte die Pilotstudie beantworten, ob die SAM subjektiv eine hohe Zufriedenheit bei den Teilnehmenden erzeugt, ob eine realistische Umgebung dargestellt werden kann und ob eine Simulation in der SAM das Stressempfinden erh&#246;ht. Es ist auch zu beachten, dass die Pilotstudie und die SIMARENA-Studie nicht verblindet waren. Insgesamt nahmen nur wenige Studierende mit unterschiedlichem Ausbildungsstand freiwillig an den Untersuchungen teil, was auch auf eine hohe Vorselektion hindeuten kann. Daher lassen sich die Ergebnisse nicht auf Rettungsdienstpersonal verallgemeinern. Andere Videoprojektionen, &#196;nderungen der Umgebungsger&#228;usche sowie der Einsatz von Requisiten, Wind und Nebel h&#228;tten das Stressempfinden und die Reanimationsqualtit&#228;t ver&#228;ndern k&#246;nnen. Insgesamt vergleichen die Studien Simulationen ohne zus&#228;tzliche Umgebungsdarstellung mit Simulationen mit einer Umgebungsdarstellung durch die SAM. Dieser Ansatz wurde gew&#228;hlt, weil er den zus&#228;tzlichen Vorteil einer Simulationsarena untersucht.</Pgraph></TextBlock>
    <TextBlock name="5. Conclusion" linked="yes" language="en">
      <MainHeadline>5. Conclusion</MainHeadline><Pgraph>The SAM is the first affordable 180&#176; simulation arena in Germany that enables emergency medical simulations in a realistic, rapidly interchangeable, secure, and standardized environment. It increases stress levels without reducing the quality of resuscitation, providing an optimal learning environment in which stress levels can be tailored to the participants&#39; learning objectives through various parameters.</Pgraph></TextBlock>
    <TextBlock name="5. Schlussfolgerung" linked="yes" language="de">
      <MainHeadline>5. Schlussfolgerung</MainHeadline><Pgraph>Die SAM ist die erste kosteng&#252;nstige 180&#176; Simulationsarena in Deutschland, die notfallmedizinische Simulationen in einer realistischen, sicheren, schnell austauschbaren und standardisierten Umgebung erm&#246;glicht. Sie erh&#246;ht das Stressempfinden, ohne die Reanimationsqualit&#228;t zu beeintr&#228;chtigen und bietet eine optimale Lernumgebung, in der das Stressniveau durch verschiedene Parameter an die Lernziele der Teilnehmenden angepasst werden kann.</Pgraph></TextBlock>
    <TextBlock name="Authors&#8217; ORCIDs" linked="yes" language="en">
      <MainHeadline>Authors&#8217; ORCIDs</MainHeadline><Pgraph><UnorderedList><ListItem level="1">Niklas Leschowski: &#91;<Hyperlink href="https:&#47;&#47;orcid.org&#47;0000-0001-5319-7079">0000-0001-5319-7079</Hyperlink>&#93;</ListItem><ListItem level="1">Sabine Darius: &#91;<Hyperlink href="https:&#47;&#47;orcid.org&#47;0000-0002-8404-6406">0000-0002-8404-6406</Hyperlink>&#93;</ListItem><ListItem level="1">Irina B&#246;ckelmann: &#91;<Hyperlink href="https:&#47;&#47;orcid.org&#47;0000-0002-3905-3527">0000-0002-3905-3527</Hyperlink>&#93;</ListItem><ListItem level="1">Katrin Borucki: &#91;<Hyperlink href="https:&#47;&#47;orcid.org&#47;0000-0003-3648-2657">0000-0003-3648-2657</Hyperlink>&#93;</ListItem><ListItem level="1">R&#252;diger C. Braun-Dullaeus: &#91;<Hyperlink href="https:&#47;&#47;orcid.org&#47;0000-0003-3888-6532">0000-0003-3888-6532</Hyperlink>&#93;</ListItem></UnorderedList></Pgraph></TextBlock>
    <TextBlock name="ORCIDs der Autor&#42;innen" linked="yes" language="de">
      <MainHeadline>ORCIDs der Autor&#42;innen</MainHeadline><Pgraph><UnorderedList><ListItem level="1">Niklas Leschowski: &#91;<Hyperlink href="https:&#47;&#47;orcid.org&#47;0000-0001-5319-7079">0000-0001-5319-7079</Hyperlink>&#93;</ListItem><ListItem level="1">Sabine Darius: &#91;<Hyperlink href="https:&#47;&#47;orcid.org&#47;0000-0002-8404-6406">0000-0002-8404-6406</Hyperlink>&#93;</ListItem><ListItem level="1">Irina B&#246;ckelmann: &#91;<Hyperlink href="https:&#47;&#47;orcid.org&#47;0000-0002-3905-3527">0000-0002-3905-3527</Hyperlink>&#93;</ListItem><ListItem level="1">Katrin Borucki: &#91;<Hyperlink href="https:&#47;&#47;orcid.org&#47;0000-0003-3648-2657">0000-0003-3648-2657</Hyperlink>&#93;</ListItem><ListItem level="1">R&#252;diger C. Braun-Dullaeus: &#91;<Hyperlink href="https:&#47;&#47;orcid.org&#47;0000-0003-3888-6532">0000-0003-3888-6532</Hyperlink>&#93;</ListItem></UnorderedList></Pgraph></TextBlock>
    <TextBlock name="Acknowledgements" linked="yes" language="en">
      <MainHeadline>Acknowledgements</MainHeadline><Pgraph>We would like to thank Dr. Winkler-Stuck, Korinna Wendt, the dean&#8217;s office, the commission for studies and education, and the student council for their support in the development and implementation of the SimArena Magdeburg.</Pgraph></TextBlock>
    <TextBlock name="Danksagungen" linked="yes" language="de">
      <MainHeadline>Danksagungen</MainHeadline><Pgraph>Wir bedanken uns bei Frau Dr. Winkler-Stuck, Frau Korinna Wendt, dem Studiendekanat, der Kommission f&#252;r Studium und Lehre und dem Fachschaftsrat f&#252;r ihre Unterst&#252;tzung bei der Entwicklung und Umsetzung der SimArena Magdeburg.</Pgraph></TextBlock>
    <TextBlock name="Competing interests" linked="yes" language="en">
      <MainHeadline>Competing interests</MainHeadline><Pgraph>The authors declare that they have no competing interests. </Pgraph></TextBlock>
    <TextBlock name="Interessenkonflikt" linked="yes" language="de">
      <MainHeadline>Interessenkonflikt</MainHeadline><Pgraph>Die Autor&#42;innen erkl&#228;ren, dass sie keinen Interessenkonflikt im Zusammenhang mit diesem Artikel haben.</Pgraph></TextBlock>
    <References linked="yes">
      <Reference refNo="1">
        <RefAuthor>Marschall B</RefAuthor>
        <RefTitle></RefTitle>
        <RefYear>2008</RefYear>
        <RefBookTitle>&#8220;Beam me in, Scotty&#8221;: das SimuScape&#169;</RefBookTitle>
        <RefPage></RefPage>
        <RefTotal>Marschall B. &#8220;Beam me in, Scotty&#8221;: das SimuScape&#169;. M&#252;nster: Universit&#228;t M&#252;nster, medcampus; 2008. Zug&#228;nglich unter&#47;available from: https:&#47;&#47;medicampus.uni-muenster.de&#47;5082.html</RefTotal>
        <RefLink>https:&#47;&#47;medicampus.uni-muenster.de&#47;5082.html</RefLink>
      </Reference>
      <Reference refNo="2">
        <RefAuthor>Medizinische Fakult&#228;t Universit&#228;t Duisburg-Essen</RefAuthor>
        <RefTitle></RefTitle>
        <RefYear>2015</RefYear>
        <RefBookTitle>SimArena - Die etwas andere Lernerfahrung</RefBookTitle>
        <RefPage></RefPage>
        <RefTotal>Medizinische Fakult&#228;t Universit&#228;t Duisburg-Essen. SimArena - Die etwas andere Lernerfahrung. Duisburg, Essen: Universit&#228;t Duisburg-Essen, Med. Fakult&#228;t; 2015. Zug&#228;nglich unter&#47;available from: https:&#47;&#47;www.uni-due.de&#47;&#126;ht0209&#47;lab2014&#47;lehrende&#47;das-skillslab-im-lehr-und-lernzentrum&#47;simarena&#47;</RefTotal>
        <RefLink>https:&#47;&#47;www.uni-due.de&#47;&#126;ht0209&#47;lab2014&#47;lehrende&#47;das-skillslab-im-lehr-und-lernzentrum&#47;simarena&#47;</RefLink>
      </Reference>
      <Reference refNo="3">
        <RefAuthor>Fidrich A</RefAuthor>
        <RefAuthor>Grondstein R</RefAuthor>
        <RefAuthor>Groetschel H</RefAuthor>
        <RefTitle></RefTitle>
        <RefYear>2015</RefYear>
        <RefBookTitle>Innovative Technik in der praktischen Lehre: Eine interaktive Vorstellung der SimArena des SkillsLab Essen. Internationales SKILLSLAB Symposium Internationalisierung von SkillsLabs</RefBookTitle>
        <RefPage>51-52</RefPage>
        <RefTotal>Fidrich A, Grondstein R, Groetschel H. Innovative Technik in der praktischen Lehre: Eine interaktive Vorstellung der SimArena des SkillsLab Essen. Internationales SKILLSLAB Symposium Internationalisierung von SkillsLabs. 2015. p.51-52. Zug&#228;nglich unter&#47;available from: https:&#47;&#47;student.uniklinikum-leipzig.de&#47;lernklinik&#47;doc&#47;Skillslab&#95;Symposium&#95;2015.pdf</RefTotal>
        <RefLink>https:&#47;&#47;student.uniklinikum-leipzig.de&#47;lernklinik&#47;doc&#47;Skillslab&#95;Symposium&#95;2015.pdf</RefLink>
      </Reference>
      <Reference refNo="4">
        <RefAuthor>Crasm&#246;ller M</RefAuthor>
        <RefAuthor>Fritzemeier S</RefAuthor>
        <RefAuthor>Fidrich A</RefAuthor>
        <RefAuthor>Groetschel H</RefAuthor>
        <RefTitle>Notfall Simulation &#8211; Implementierung von &#8222;SimKursen&#8220; im SkillsLab Essen</RefTitle>
        <RefYear>2016</RefYear>
        <RefBookTitle>Jahrestagung der Gesellschaft f&#252;r Medizinische Ausbildung (GMA). Bern, 14-17.09.2016.</RefBookTitle>
        <RefPage>DocP5-691</RefPage>
        <RefTotal>Crasm&#246;ller M, Fritzemeier S, Fidrich A, Groetschel H. Notfall Simulation &#8211; Implementierung von &#8222;SimKursen&#8220; im SkillsLab Essen. In: Jahrestagung der Gesellschaft f&#252;r Medizinische Ausbildung (GMA). Bern, 14-17.09.2016. D&#252;sseldorf: German Medical Science GMS Publishing House; 2016. DocP5-691. DOI: 10.3025&#47;16gma340</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.3025&#47;16gma340</RefLink>
      </Reference>
      <Reference refNo="5">
        <RefAuthor>Kaplow M</RefAuthor>
        <RefTitle>SimuScape: Virtuelle Trainingsumgebung f&#252;r medizinische Alltagssituationen. idw - Informationsdienst Wissenschaft</RefTitle>
        <RefYear>2008</RefYear>
        <RefJournal>idw - Informationsdienst Wissenschaft</RefJournal>
        <RefPage></RefPage>
        <RefTotal>Kaplow M. SimuScape: Virtuelle Trainingsumgebung f&#252;r medizinische Alltagssituationen. idw - Informationsdienst Wissenschaft. 20.11.2008. Zug&#228;nglich unter&#47;available from: https:&#47;&#47;idw-online.de&#47;de&#47;news289953</RefTotal>
        <RefLink>https:&#47;&#47;idw-online.de&#47;de&#47;news289953</RefLink>
      </Reference>
      <Reference refNo="6">
        <RefAuthor>Marschall B</RefAuthor>
        <RefTitle></RefTitle>
        <RefYear>2008</RefYear>
        <RefBookTitle>Zum Hausbesuch ins &#8222;Holo-Deck&#8220;: Er&#246;ffnung des ambulanten Bereichs im Studienhospital M&#252;nster</RefBookTitle>
        <RefPage></RefPage>
        <RefTotal>Marschall B. Zum Hausbesuch ins &#8222;Holo-Deck&#8220;: Er&#246;ffnung des ambulanten Bereichs im Studienhospital M&#252;nster. M&#252;nster: Universit&#228;t M&#252;nster, medcampus; 2008. Zug&#228;nglich unter&#47;available from: https:&#47;&#47;medicampus.uni-muenster.de&#47;4067.html</RefTotal>
        <RefLink>https:&#47;&#47;medicampus.uni-muenster.de&#47;4067.html</RefLink>
      </Reference>
      <Reference refNo="7">
        <RefAuthor>Thies AL</RefAuthor>
        <RefAuthor>Weissenstein A</RefAuthor>
        <RefAuthor>Haulsen I</RefAuthor>
        <RefAuthor>Marschall B</RefAuthor>
        <RefAuthor>Friederichs H</RefAuthor>
        <RefTitle>Experiences with a simulated learning environment - the SimuScape&#169;</RefTitle>
        <RefYear>2014</RefYear>
        <RefJournal>J Technol Sci Educ</RefJournal>
        <RefPage></RefPage>
        <RefTotal>Thies AL, Weissenstein A, Haulsen I, Marschall B, Friederichs H. Experiences with a simulated learning environment - the SimuScape&#169;: Virtual environments in medical education. J Technol Sci Educ. 2014;4(1). DOI: 10.3926&#47;jotse.88</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.3926&#47;jotse.88</RefLink>
      </Reference>
      <Reference refNo="8">
        <RefAuthor>Goolsby C</RefAuthor>
        <RefAuthor>Vest R</RefAuthor>
        <RefAuthor>Goodwin T</RefAuthor>
        <RefTitle>New Wide Area Virtual Environment (WAVE) Medical Education</RefTitle>
        <RefYear>2014</RefYear>
        <RefJournal>Mil Med</RefJournal>
        <RefPage>38-41</RefPage>
        <RefTotal>Goolsby C, Vest R, Goodwin T. New Wide Area Virtual Environment (WAVE) Medical Education. Mil Med. 2014;179(1):38-41. DOI: 10.7205&#47;MILMED-D-13-00310</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.7205&#47;MILMED-D-13-00310</RefLink>
      </Reference>
      <Reference refNo="9">
        <RefAuthor>Wier GS</RefAuthor>
        <RefAuthor>Tree R</RefAuthor>
        <RefAuthor>Nusr R</RefAuthor>
        <RefTitle>Training Effectiveness of a Wide Area Virtual Environment in Medical Simulation</RefTitle>
        <RefYear>2017</RefYear>
        <RefJournal>Simul Healthc</RefJournal>
        <RefPage>28-40</RefPage>
        <RefTotal>Wier GS, Tree R, Nusr R. Training Effectiveness of a Wide Area Virtual Environment in Medical Simulation. Simul Healthc. 2017;12(1):28-40. DOI: 10.1097&#47;SIH.0000000000000207</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1097&#47;SIH.0000000000000207</RefLink>
      </Reference>
      <Reference refNo="10">
        <RefAuthor>Liu A</RefAuthor>
        <RefAuthor>Acosta E</RefAuthor>
        <RefAuthor>Cope J</RefAuthor>
        <RefAuthor>Henry V</RefAuthor>
        <RefAuthor>Reyes F</RefAuthor>
        <RefAuthor>Bradascio J</RefAuthor>
        <RefAuthor>Wesley Meek</RefAuthor>
        <RefTitle>The Wide Area Virtual Environment: A New Paradigm for Medical Team Training</RefTitle>
        <RefYear>2018</RefYear>
        <RefBookTitle>Augmented Cognition: Users and Contexts. AC 2018</RefBookTitle>
        <RefPage>293-304</RefPage>
        <RefTotal>Liu A, Acosta E, Cope J, Henry V, Reyes F, Bradascio J, Wesley Meek. The Wide Area Virtual Environment: A New Paradigm for Medical Team Training. In: Schmorrow D, Fidopiastis C, editors. Augmented Cognition: Users and Contexts. AC 2018. Cham: Springer Verlag; 2018. (Lecture Notes in Computer Science; 10916). p.293-304. DOI: 10.1007&#47;978-3-319-91467-1&#95;23</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1007&#47;978-3-319-91467-1&#95;23</RefLink>
      </Reference>
      <Reference refNo="11">
        <RefAuthor>Urban B</RefAuthor>
        <RefAuthor>Lazarovici M</RefAuthor>
        <RefAuthor>Sandmeyer B</RefAuthor>
        <RefTitle>Simulation in der Notfallmedizin &#8211; station&#228;re Simulation</RefTitle>
        <RefYear>2018</RefYear>
        <RefBookTitle>Simulation in der Medizin</RefBookTitle>
        <RefPage>309-335</RefPage>
        <RefTotal>Urban B, Lazarovici M, Sandmeyer B. Simulation in der Notfallmedizin &#8211; station&#228;re Simulation. In: St. Pierre M, Breuer G, editors. Simulation in der Medizin. Berlin, Heidelberg: Springer; 2018. p.309-335. DOI: 10.1007&#47;978-3-662-54566-9&#95;23</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1007&#47;978-3-662-54566-9&#95;23</RefLink>
      </Reference>
      <Reference refNo="12">
        <RefAuthor>Friedrich T</RefAuthor>
        <RefAuthor>Langner M</RefAuthor>
        <RefAuthor>Sigmund P</RefAuthor>
        <RefTitle>Simulation in der Rettungsdienstausbildung</RefTitle>
        <RefYear>2018</RefYear>
        <RefBookTitle>Simulation in der Medizin</RefBookTitle>
        <RefPage>435-443</RefPage>
        <RefTotal>Friedrich T, Langner M, Sigmund P. Simulation in der Rettungsdienstausbildung. In: St. Pierre M, Breuer G, editors. Simulation in der Medizin. Berlin, Heidelberg: Springer; 2018. p.435-443. DOI: 10.1007&#47;978-3-662-54566-9&#95;29</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1007&#47;978-3-662-54566-9&#95;29</RefLink>
      </Reference>
      <Reference refNo="13">
        <RefAuthor>Wilkerson W</RefAuthor>
        <RefAuthor>Avstreih D</RefAuthor>
        <RefAuthor>Gruppen L</RefAuthor>
        <RefAuthor>Beier KP</RefAuthor>
        <RefAuthor>Woolliscroft J</RefAuthor>
        <RefTitle>Using immersive simulation for training first responders for mass casualty incidents</RefTitle>
        <RefYear>200</RefYear>
        <RefJournal>Acad Emerg Med</RefJournal>
        <RefPage>1152-1159</RefPage>
        <RefTotal>Wilkerson W, Avstreih D, Gruppen L, Beier KP, Woolliscroft J. Using immersive simulation for training first responders for mass casualty incidents. Acad Emerg Med. 200;15(11):1152-1159. DOI: 10.1111&#47;j.1553-2712.2008.00223.x</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1111&#47;j.1553-2712.2008.00223.x</RefLink>
      </Reference>
      <Reference refNo="14">
        <RefAuthor>Gisin S</RefAuthor>
        <RefTitle>Bitte einsteigen: Das Simulationserlebnis startet hier</RefTitle>
        <RefYear>2018</RefYear>
        <RefBookTitle>Simulation in der Medizin</RefBookTitle>
        <RefPage>249-260</RefPage>
        <RefTotal>Gisin S. Bitte einsteigen: Das Simulationserlebnis startet hier. In: St. Pierre M, Breuer G, editors. Simulation in der Medizin. Berlin, Heidelberg: Springer; 2018. p.249-260. DOI: 10.1007&#47;978-3-662-54566-9&#95;18</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1007&#47;978-3-662-54566-9&#95;18</RefLink>
      </Reference>
      <Reference refNo="15">
        <RefAuthor>Hoitz J</RefAuthor>
        <RefAuthor>Braun M</RefAuthor>
        <RefAuthor>Schneidereit L</RefAuthor>
        <RefAuthor>Juri&#263; M</RefAuthor>
        <RefAuthor>G&#246;rsch C</RefAuthor>
        <RefAuthor>R&#246;hrborn K</RefAuthor>
        <RefTitle>Simulationsausbildung im Sanit&#228;tsdienst der Bundeswehr</RefTitle>
        <RefYear>2018</RefYear>
        <RefBookTitle>Simulation in der Medizin</RefBookTitle>
        <RefPage>409-433</RefPage>
        <RefTotal>Hoitz J, Braun M, Schneidereit L, Juri&#263; M, G&#246;rsch C, R&#246;hrborn K. Simulationsausbildung im Sanit&#228;tsdienst der Bundeswehr. In: St. Pierre M, Breuer G, editors. Simulation in der Medizin. Berlin, Heidelberg: Springer; 2018. p.409-433. DOI: 10.1007&#47;978-3-662-54566-9&#95;28</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1007&#47;978-3-662-54566-9&#95;28</RefLink>
      </Reference>
      <Reference refNo="16">
        <RefAuthor>Stein D</RefAuthor>
        <RefAuthor>Schwerdtfeger K</RefAuthor>
        <RefAuthor>Nickel EA</RefAuthor>
        <RefAuthor>Russo SG</RefAuthor>
        <RefTitle>Wie im wahren Leben: Simulation und Realit&#228;tsn&#228;he</RefTitle>
        <RefYear>2018</RefYear>
        <RefBookTitle>Simulation in der Medizin</RefBookTitle>
        <RefPage>131-142</RefPage>
        <RefTotal>Stein D, Schwerdtfeger K, Nickel EA, Russo SG. Wie im wahren Leben: Simulation und Realit&#228;tsn&#228;he. In: St. Pierre M, Breuer G, editors. Simulation in der Medizin. Berlin, Heidelberg: Springer Berlin Heidelberg; 2018. p.131-142. DOI: 10.1007&#47;978-3-662-54566-9&#95;11</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1007&#47;978-3-662-54566-9&#95;11</RefLink>
      </Reference>
      <Reference refNo="17">
        <RefAuthor>Vincent A</RefAuthor>
        <RefAuthor>Semmer NK</RefAuthor>
        <RefAuthor>Becker C</RefAuthor>
        <RefAuthor>Beck K</RefAuthor>
        <RefAuthor>Tschan F</RefAuthor>
        <RefAuthor>Bobst C</RefAuthor>
        <RefAuthor>Schuetz P</RefAuthor>
        <RefAuthor>Marsch S</RefAuthor>
        <RefAuthor>Hunziker S</RefAuthor>
        <RefTitle>Does stress influence the performance of cardiopulmonary resuscitation&#63; A narrative review of the literature</RefTitle>
        <RefYear>2021</RefYear>
        <RefJournal>J Crit Care</RefJournal>
        <RefPage>223-230</RefPage>
        <RefTotal>Vincent A, Semmer NK, Becker C, Beck K, Tschan F, Bobst C, Schuetz P, Marsch S, Hunziker S. Does stress influence the performance of cardiopulmonary resuscitation&#63; A narrative review of the literature. J Crit Care. 2021;63:223-230. DOI: 10.1016&#47;j.jcrc.2020.09.020</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1016&#47;j.jcrc.2020.09.020</RefLink>
      </Reference>
      <Reference refNo="18">
        <RefAuthor>Laux L</RefAuthor>
        <RefAuthor>Glanzmann P</RefAuthor>
        <RefAuthor>Schaffner P</RefAuthor>
        <RefAuthor>Spielberger CD</RefAuthor>
        <RefTitle></RefTitle>
        <RefYear>1981</RefYear>
        <RefBookTitle>Das State-Trait-Angstinventar (STAI): theoretische Grundlagen und Handanweisung</RefBookTitle>
        <RefPage></RefPage>
        <RefTotal>Laux L, Glanzmann P, Schaffner P, Spielberger CD. Das State-Trait-Angstinventar (STAI): theoretische Grundlagen und Handanweisung. Weinheim: Beltz; 1981.</RefTotal>
      </Reference>
      <Reference refNo="19">
        <RefAuthor>Minow A</RefAuthor>
        <RefAuthor>B&#246;ckelmann I</RefAuthor>
        <RefTitle>Beanspruchung, objektive Leistung und Gebrauchstauglichkeit bei simulierten Montageprozessen mit digitalen Arbeitsanweisungen</RefTitle>
        <RefYear>2020</RefYear>
        <RefJournal>Zentralbl Arbeitsmed Arbeitsschutz Ergon</RefJournal>
        <RefPage>47-56</RefPage>
        <RefTotal>Minow A, B&#246;ckelmann I. Beanspruchung, objektive Leistung und Gebrauchstauglichkeit bei simulierten Montageprozessen mit digitalen Arbeitsanweisungen. Zentralbl Arbeitsmed Arbeitsschutz Ergon. 2020;70(2):47-56. DOI: 10.1007&#47;s40664-019-00372-8</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1007&#47;s40664-019-00372-8</RefLink>
      </Reference>
      <Reference refNo="20">
        <RefAuthor>Nitsch JR</RefAuthor>
        <RefAuthor>Udris I</RefAuthor>
        <RefTitle>Die Eigenzustandsskala (EZ-Skala) - Ein Verfahren zur hierarchisch-mehrdimensionalen Befindlichkeitsskalierung</RefTitle>
        <RefYear>1976</RefYear>
        <RefBookTitle>Eigenzustandskala (EZ-Skala): ein Verfahren zur hierarchisch-mehrdimensionalen Befindlichkeitsskalierung</RefBookTitle>
        <RefPage>81-102</RefPage>
        <RefTotal>Nitsch JR, Udris I. Die Eigenzustandsskala (EZ-Skala) - Ein Verfahren zur hierarchisch-mehrdimensionalen Befindlichkeitsskalierung. In: Nitsch JR, editor. Eigenzustandskala (EZ-Skala): ein Verfahren zur hierarchisch-mehrdimensionalen Befindlichkeitsskalierung. 1. Auflage.  Bad Homburg: Limpert-Verlag; 1976. p.81-102.</RefTotal>
      </Reference>
      <Reference refNo="21">
        <RefAuthor>Dias RD</RefAuthor>
        <RefAuthor>Scalabrini-Neto A</RefAuthor>
        <RefTitle>Acute stress in residents playing different roles during emergency simulations: a preliminary study</RefTitle>
        <RefYear>2017</RefYear>
        <RefJournal>Int J Med Educ</RefJournal>
        <RefPage>239-243</RefPage>
        <RefTotal>Dias RD, Scalabrini-Neto A. Acute stress in residents playing different roles during emergency simulations: a preliminary study. Int J Med Educ. 2017;8:239-243. DOI: 10.5116&#47;ijme.5929.60f1</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.5116&#47;ijme.5929.60f1</RefLink>
      </Reference>
      <Reference refNo="22">
        <RefAuthor>Daglius Dias R</RefAuthor>
        <RefAuthor>Scalabrini Neto A</RefAuthor>
        <RefTitle>Stress levels during emergency care: A comparison between reality and simulated scenarios</RefTitle>
        <RefYear>2016</RefYear>
        <RefJournal>J Crit Care</RefJournal>
        <RefPage>8-13</RefPage>
        <RefTotal>Daglius Dias R, Scalabrini Neto A. Stress levels during emergency care: A comparison between reality and simulated scenarios. J Crit Care. 2016;33:8-13. DOI: 10.1016&#47;j.jcrc.2016.02.010</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1016&#47;j.jcrc.2016.02.010</RefLink>
      </Reference>
      <Reference refNo="23">
        <RefAuthor>Engert V</RefAuthor>
        <RefAuthor>Vogel S</RefAuthor>
        <RefAuthor>Efanov SI</RefAuthor>
        <RefAuthor>Duchesne A</RefAuthor>
        <RefAuthor>Corbo V</RefAuthor>
        <RefAuthor>Ali N</RefAuthor>
        <RefAuthor>Pruessner JC</RefAuthor>
        <RefTitle>Investigation into the cross-correlation of salivary cortisol and alpha-amylase responses to psychological stress</RefTitle>
        <RefYear>2011</RefYear>
        <RefJournal>Psychoneuroendocrinology</RefJournal>
        <RefPage>1294-1302</RefPage>
        <RefTotal>Engert V, Vogel S, Efanov SI, Duchesne A, Corbo V, Ali N, Pruessner JC. Investigation into the cross-correlation of salivary cortisol and alpha-amylase responses to psychological stress. Psychoneuroendocrinology. 2011;36(9):1294-1302. DOI: 10.1016&#47;j.psyneuen.2011.02.018</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1016&#47;j.psyneuen.2011.02.018</RefLink>
      </Reference>
      <Reference refNo="24">
        <RefAuthor>Roche Diagnostics GmbH</RefAuthor>
        <RefTitle></RefTitle>
        <RefYear>2019</RefYear>
        <RefBookTitle>cobas AMYL2</RefBookTitle>
        <RefPage>1-5</RefPage>
        <RefTotal>Roche Diagnostics GmbH. cobas AMYL2. 2019. p.1-5. Zug&#228;nglich unter&#47;available from: https:&#47;&#47;labogids.sintmaria.be&#47;sites&#47;default&#47;files&#47;files&#47;amyl2&#95;2018-12&#95;v10.pdf</RefTotal>
        <RefLink>https:&#47;&#47;labogids.sintmaria.be&#47;sites&#47;default&#47;files&#47;files&#47;amyl2&#95;2018-12&#95;v10.pdf</RefLink>
      </Reference>
      <Reference refNo="25">
        <RefAuthor>Takai N</RefAuthor>
        <RefAuthor>Yamaguchi M</RefAuthor>
        <RefAuthor>Aragaki T</RefAuthor>
        <RefAuthor>Eto K</RefAuthor>
        <RefAuthor>Uchihashi K</RefAuthor>
        <RefAuthor>Nishikawa Y</RefAuthor>
        <RefTitle>Effect of psychological stress on the salivary cortisol and amylase levels in healthy young adults</RefTitle>
        <RefYear>2004</RefYear>
        <RefJournal>Arch Oral Biol</RefJournal>
        <RefPage>963-968</RefPage>
        <RefTotal>Takai N, Yamaguchi M, Aragaki T, Eto K, Uchihashi K, Nishikawa Y. Effect of psychological stress on the salivary cortisol and amylase levels in healthy young adults. Arch Oral Biol. 2004;49(12):963-968. DOI: 10.1016&#47;j.archoralbio.2004.06.007</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1016&#47;j.archoralbio.2004.06.007</RefLink>
      </Reference>
      <Reference refNo="26">
        <RefAuthor>Laerdal</RefAuthor>
        <RefTitle></RefTitle>
        <RefYear>2016</RefYear>
        <RefBookTitle>SimPad Benutzerhandbuch</RefBookTitle>
        <RefPage></RefPage>
        <RefTotal>Laerdal. SimPad Benutzerhandbuch. 2016. Zug&#228;nglich unter&#47;available from: https:&#47;&#47;cdn.laerdal.com&#47;downloads&#47;f4391&#47;ug;&#95;simpad-(d).pdf</RefTotal>
        <RefLink>https:&#47;&#47;cdn.laerdal.com&#47;downloads&#47;f4391&#47;ug;&#95;simpad-(d).pdf</RefLink>
      </Reference>
      <Reference refNo="27">
        <RefAuthor>Laerdal Medical</RefAuthor>
        <RefTitle></RefTitle>
        <RefYear>2020</RefYear>
        <RefBookTitle>Laerdal Scoring</RefBookTitle>
        <RefPage></RefPage>
        <RefTotal>Laerdal Medical. Laerdal Scoring. 2020.</RefTotal>
      </Reference>
      <Reference refNo="28">
        <RefAuthor>Deutscher Rat f&#252;r Wiederbelebung - German Resuscitation Council e.V.</RefAuthor>
        <RefTitle></RefTitle>
        <RefYear>2015</RefYear>
        <RefBookTitle>Reanimation 2015 - Leitlinien kompakt</RefBookTitle>
        <RefPage></RefPage>
        <RefTotal>Deutscher Rat f&#252;r Wiederbelebung - German Resuscitation Council e.V. Reanimation 2015 - Leitlinien kompakt. Ulm: Deutscher Rat f&#252;r Wiederbelebung - German Rescitation Conciel e.V.; 2015. Zug&#228;nglich unter&#47;available from: https:&#47;&#47;www.grc-org.de&#47;downloads&#47;GRC-Leitlinien-2015-Kompakt.pdf</RefTotal>
        <RefLink>https:&#47;&#47;www.grc-org.de&#47;downloads&#47;GRC-Leitlinien-2015-Kompakt.pdf</RefLink>
      </Reference>
      <Reference refNo="29">
        <RefAuthor>Mills BW</RefAuthor>
        <RefAuthor>Carter OBJ</RefAuthor>
        <RefAuthor>Rudd CJ</RefAuthor>
        <RefAuthor>Claxton LA</RefAuthor>
        <RefAuthor>Ross NP</RefAuthor>
        <RefAuthor>Strobel NA</RefAuthor>
        <RefTitle>Effects of Low- Versus High-Fidelity Simulations on the Cognitive Burden and Performance of Entry-Level Paramedicine Students: A Mixed-Methods Comparison Trial Using Eye-Tracking, Continuous Heart Rate, Difficulty Rating Scales, Video Observation and Interviews</RefTitle>
        <RefYear>2016</RefYear>
        <RefJournal>Simul Healthc</RefJournal>
        <RefPage>10-18</RefPage>
        <RefTotal>Mills BW, Carter OBJ, Rudd CJ, Claxton LA, Ross NP, Strobel NA. Effects of Low- Versus High-Fidelity Simulations on the Cognitive Burden and Performance of Entry-Level Paramedicine Students: A Mixed-Methods Comparison Trial Using Eye-Tracking, Continuous Heart Rate, Difficulty Rating Scales, Video Observation and Interviews. Simul Healthc. 2016;11(1):10-18. DOI: 10.1097&#47;SIH.0000000000000119</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1097&#47;SIH.0000000000000119</RefLink>
      </Reference>
      <Reference refNo="30">
        <RefAuthor>Sammito S</RefAuthor>
        <RefAuthor>Thielmann B</RefAuthor>
        <RefAuthor>Seibt R</RefAuthor>
        <RefAuthor>Klussmann A</RefAuthor>
        <RefAuthor>Weippert M</RefAuthor>
        <RefTitle>Occupational medical guideline</RefTitle>
        <RefYear>2015</RefYear>
        <RefJournal>Arbeitsmed Sozialmed Umweltmed</RefJournal>
        <RefPage>1-15</RefPage>
        <RefTotal>Sammito S, Thielmann B, Seibt R, Klussmann A, Weippert M. Occupational medical guideline. Arbeitsmed Sozialmed Umweltmed. 2015:1-15.</RefTotal>
      </Reference>
      <Reference refNo="31">
        <RefAuthor>Sammito S</RefAuthor>
        <RefAuthor>Thielmann B</RefAuthor>
        <RefAuthor>Seibt R</RefAuthor>
        <RefAuthor>Klussmann A</RefAuthor>
        <RefAuthor>Weippert M</RefAuthor>
        <RefAuthor>B&#246;ckelmarn I</RefAuthor>
        <RefTitle>Nutzung der Herzschlagfrequenz und der Herzfrequenzvariabilit&#228;t in der Arbeitsmedizin und der Arbeitswissenschaft</RefTitle>
        <RefYear>2016</RefYear>
        <RefJournal>Arbeitsmed Sozialmed Umweltmed</RefJournal>
        <RefPage>123-141</RefPage>
        <RefTotal>Sammito S, Thielmann B, Seibt R, Klussmann A, Weippert M, B&#246;ckelmarn I. Nutzung der Herzschlagfrequenz und der Herzfrequenzvariabilit&#228;t in der Arbeitsmedizin und der Arbeitswissenschaft. Arbeitsmed Sozialmed Umweltmed. 2016;51(2):123-141.</RefTotal>
      </Reference>
      <Reference refNo="32">
        <RefAuthor>Bowyer MW</RefAuthor>
        <RefAuthor>Streete KA</RefAuthor>
        <RefAuthor>Muniz GM</RefAuthor>
        <RefAuthor>Liu AV</RefAuthor>
        <RefTitle>Immersive Virtual Environments for Medical Training</RefTitle>
        <RefYear>2008</RefYear>
        <RefJournal>Semin Colon Rectal Surg</RefJournal>
        <RefPage>90-97</RefPage>
        <RefTotal>Bowyer MW, Streete KA, Muniz GM, Liu AV. Immersive Virtual Environments for Medical Training. Semin Colon Rectal Surg. 2008;19(2):90-97. DOI: 10.1053&#47;j.scrs.2008.02.005</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1053&#47;j.scrs.2008.02.005</RefLink>
      </Reference>
      <Reference refNo="33">
        <RefAuthor>Piquette D</RefAuthor>
        <RefAuthor>Tarshis J</RefAuthor>
        <RefAuthor>Sinuff T</RefAuthor>
        <RefAuthor>Fowler RA</RefAuthor>
        <RefAuthor>Pinto R</RefAuthor>
        <RefAuthor>Leblanc VR</RefAuthor>
        <RefTitle>Impact of Acute Stress on Resident Performance During Simulated Resuscitation Episodes: A Prospective Randomized Cross-Over Study</RefTitle>
        <RefYear>2014</RefYear>
        <RefJournal>Teach Learn Med</RefJournal>
        <RefPage>9-16</RefPage>
        <RefTotal>Piquette D, Tarshis J, Sinuff T, Fowler RA, Pinto R, Leblanc VR. Impact of Acute Stress on Resident Performance During Simulated Resuscitation Episodes: A Prospective Randomized Cross-Over Study. Teach Learn Med. 2014;26(1):9-16. DOI: 10.1080&#47;10401334.2014.859932</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1080&#47;10401334.2014.859932</RefLink>
      </Reference>
      <Reference refNo="34">
        <RefAuthor>DeMaria Jr S</RefAuthor>
        <RefAuthor>Bryson EO</RefAuthor>
        <RefAuthor>Mooney TJ</RefAuthor>
        <RefAuthor>Silverstein JH</RefAuthor>
        <RefAuthor>Reich DL</RefAuthor>
        <RefAuthor>Bodian C</RefAuthor>
        <RefAuthor>Levine AI</RefAuthor>
        <RefTitle>Adding emotional stressors to training in simulated cardiopulmonary arrest enhances participant performance</RefTitle>
        <RefYear>2010</RefYear>
        <RefJournal>Med Educ</RefJournal>
        <RefPage>1006-1015</RefPage>
        <RefTotal>DeMaria Jr S, Bryson EO, Mooney TJ, Silverstein JH, Reich DL, Bodian C, Levine AI. Adding emotional stressors to training in simulated cardiopulmonary arrest enhances participant performance. Med Educ. 2010;44(10):1006-1015. DOI: 10.1111&#47;j.1365-2923.2010.03775.x</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1111&#47;j.1365-2923.2010.03775.x</RefLink>
      </Reference>
      <Reference refNo="35">
        <RefAuthor>Harvey A</RefAuthor>
        <RefAuthor>Bandiera G</RefAuthor>
        <RefAuthor>Nathens AB</RefAuthor>
        <RefAuthor>LeBlanc VR</RefAuthor>
        <RefTitle>Impact of stress on resident performance in simulated trauma scenarios</RefTitle>
        <RefYear>2012</RefYear>
        <RefJournal>J Trauma Acute Care Surg</RefJournal>
        <RefPage>497-503</RefPage>
        <RefTotal>Harvey A, Bandiera G, Nathens AB, LeBlanc VR. Impact of stress on resident performance in simulated trauma scenarios. J Trauma Acute Care Surg. 2012;72(2):497-503. DOI: 10.1097&#47;ta.0b013e31821f84be</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1097&#47;ta.0b013e31821f84be</RefLink>
      </Reference>
      <Reference refNo="36">
        <RefAuthor>Harvey A</RefAuthor>
        <RefAuthor>Nathens AB</RefAuthor>
        <RefAuthor>Bandiera G</RefAuthor>
        <RefAuthor>LeBlanc VR</RefAuthor>
        <RefTitle>Threat and challenge: cognitive appraisal and stress responses in simulated trauma resuscitations</RefTitle>
        <RefYear>2010</RefYear>
        <RefJournal>Med Educ</RefJournal>
        <RefPage>587-594</RefPage>
        <RefTotal>Harvey A, Nathens AB, Bandiera G, LeBlanc VR. Threat and challenge: cognitive appraisal and stress responses in simulated trauma resuscitations. Med Educ. 2010;44(6):587-594. DOI: 10.1111&#47;j.1365-2923.2010.03634.x</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1111&#47;j.1365-2923.2010.03634.x</RefLink>
      </Reference>
      <Reference refNo="37">
        <RefAuthor>Tram&#232;r L</RefAuthor>
        <RefAuthor>Becker C</RefAuthor>
        <RefAuthor>Hochstrasser S</RefAuthor>
        <RefAuthor>Marsch S</RefAuthor>
        <RefAuthor>Hunziker S</RefAuthor>
        <RefTitle>Association of electrocardiogram alterations of rescuers and performance during a simulated cardiac arrest: A prospective simulation study</RefTitle>
        <RefYear>2018</RefYear>
        <RefJournal>PLoS One</RefJournal>
        <RefPage>e0198661</RefPage>
        <RefTotal>Tram&#232;r L, Becker C, Hochstrasser S, Marsch S, Hunziker S. Association of electrocardiogram alterations of rescuers and performance during a simulated cardiac arrest: A prospective simulation study. PLoS One. 2018;13(6):e0198661. DOI: 10.1371&#47;journal.pone.0198661</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1371&#47;journal.pone.0198661</RefLink>
      </Reference>
      <Reference refNo="38">
        <RefAuthor>Dias RD</RefAuthor>
        <RefAuthor>Scalabrini Neto A</RefAuthor>
        <RefTitle>Acute stress in residents during emergency care: a study of personal and situational factors</RefTitle>
        <RefYear>2017</RefYear>
        <RefJournal>Stress</RefJournal>
        <RefPage>241-248</RefPage>
        <RefTotal>Dias RD, Scalabrini Neto A. Acute stress in residents during emergency care: a study of personal and situational factors. Stress. 2017;20(3):241-248. DOI: 10.1080&#47;10253890.2017.1325866</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1080&#47;10253890.2017.1325866</RefLink>
      </Reference>
      <Reference refNo="39">
        <RefAuthor>Valentin B</RefAuthor>
        <RefAuthor>Grottke O</RefAuthor>
        <RefAuthor>Skorning M</RefAuthor>
        <RefAuthor>Bergrath S</RefAuthor>
        <RefAuthor>Fischermann H</RefAuthor>
        <RefAuthor>R&#246;rtgen D</RefAuthor>
        <RefAuthor>Mennig MT</RefAuthor>
        <RefAuthor>Fitzner C</RefAuthor>
        <RefAuthor>M&#252;ller MP</RefAuthor>
        <RefAuthor>Kirschbaum C</RefAuthor>
        <RefAuthor>Rossaint R</RefAuthor>
        <RefAuthor>Beckers SK</RefAuthor>
        <RefTitle>Cortisol and alpha-amylase as stress response indicators during pre-hospital emergency medicine training with repetitive high-fidelity simulation and scenarios with standardized patients</RefTitle>
        <RefYear>2015</RefYear>
        <RefJournal>Scand J Trauma Resusc Emerg Med</RefJournal>
        <RefPage>31</RefPage>
        <RefTotal>Valentin B, Grottke O, Skorning M, Bergrath S, Fischermann H, R&#246;rtgen D, Mennig MT, Fitzner C, M&#252;ller MP, Kirschbaum C, Rossaint R, Beckers SK. Cortisol and alpha-amylase as stress response indicators during pre-hospital emergency medicine training with repetitive high-fidelity simulation and scenarios with standardized patients. Scand J Trauma Resusc Emerg Med. 2015;23(1):31. DOI: 10.1186&#47;s13049-015-0110-6</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1186&#47;s13049-015-0110-6</RefLink>
      </Reference>
      <Reference refNo="40">
        <RefAuthor>Peng HT</RefAuthor>
        <RefAuthor>Tenn C</RefAuthor>
        <RefAuthor>Vartanian O</RefAuthor>
        <RefAuthor>Rhind SG</RefAuthor>
        <RefAuthor>Jarmasz J</RefAuthor>
        <RefAuthor>Tien H</RefAuthor>
        <RefAuthor>Beckett A</RefAuthor>
        <RefAuthor> LT-SIM study group</RefAuthor>
        <RefTitle>Biological Response to Stress During Battlefield Trauma Training: Live Tissue Versus High-Fidelity Patient Simulator</RefTitle>
        <RefYear>2018</RefYear>
        <RefJournal>Mil Med</RefJournal>
        <RefPage>e349-e356</RefPage>
        <RefTotal>Peng HT, Tenn C, Vartanian O, Rhind SG, Jarmasz J, Tien H, Beckett A; LT-SIM study group. Biological Response to Stress During Battlefield Trauma Training: Live Tissue Versus High-Fidelity Patient Simulator. Mil Med. 2018;183(9-10):e349-e356. DOI: 10.1093&#47;milmed&#47;usx236</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1093&#47;milmed&#47;usx236</RefLink>
      </Reference>
      <Reference refNo="41">
        <RefAuthor>Chatterton RT</RefAuthor>
        <RefAuthor>Vogelsong KM</RefAuthor>
        <RefAuthor>Lu Y</RefAuthor>
        <RefAuthor>Ellman AB</RefAuthor>
        <RefAuthor>Hudgens GA</RefAuthor>
        <RefTitle>Salivary &#945;-amylase as a measure of endogenous adrenergic activity</RefTitle>
        <RefYear>1996</RefYear>
        <RefJournal>Clin Physiol</RefJournal>
        <RefPage>433-448</RefPage>
        <RefTotal>Chatterton RT, Vogelsong KM, Lu Y, Ellman AB, Hudgens GA. Salivary &#945;-amylase as a measure of endogenous adrenergic activity. Clin Physiol. 1996;16(4):433-448. DOI: 10.1111&#47;j.1475-097x.1996.tb00731.x</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1111&#47;j.1475-097x.1996.tb00731.x</RefLink>
      </Reference>
      <Reference refNo="42">
        <RefAuthor>Nater UM</RefAuthor>
        <RefAuthor>Rohleder N</RefAuthor>
        <RefTitle>Salivary alpha-amylase as a non-invasive biomarker for the sympathetic nervous system: Current state of research</RefTitle>
        <RefYear>2009</RefYear>
        <RefJournal>Psychoneuroendocrinology</RefJournal>
        <RefPage>486-496</RefPage>
        <RefTotal>Nater UM, Rohleder N. Salivary alpha-amylase as a non-invasive biomarker for the sympathetic nervous system: Current state of research. Psychoneuroendocrinology. 2009;34(4):486-496. DOI: 10.1016&#47;j.psyneuen.2009.01.014</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1016&#47;j.psyneuen.2009.01.014</RefLink>
      </Reference>
      <Reference refNo="43">
        <RefAuthor>Yerkes RM</RefAuthor>
        <RefAuthor>Dodson JD</RefAuthor>
        <RefTitle>The relation of strength of stimulus to rapidity of habit-formation</RefTitle>
        <RefYear>1908</RefYear>
        <RefJournal>J Comp Neurol Psychol</RefJournal>
        <RefPage>459-482</RefPage>
        <RefTotal>Yerkes RM, Dodson JD. The relation of strength of stimulus to rapidity of habit-formation. J Comp Neurol Psychol. 1908;18(5):459-482. DOI: 10.1002&#47;cne.920180503</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1002&#47;cne.920180503</RefLink>
      </Reference>
    </References>
    <Media>
      <Tables>
        <Table format="png">
          <MediaNo>1</MediaNo>
          <MediaID language="en">1en</MediaID>
          <MediaID language="de">1de</MediaID>
          <Caption language="en"><Pgraph><Mark1>Table 1: Material SimArena Magdeburg</Mark1></Pgraph></Caption>
          <Caption language="de"><Pgraph><Mark1>Tabelle 1: Material SimArena Magdeburg</Mark1></Pgraph></Caption>
        </Table>
        <Table format="png">
          <MediaNo>2</MediaNo>
          <MediaID language="en">2en</MediaID>
          <MediaID language="de">2de</MediaID>
          <Caption language="en"><Pgraph><Mark1>Table 2: SAM survey</Mark1></Pgraph></Caption>
          <Caption language="de"><Pgraph><Mark1>Tabelle 2: SAM-Fragebogen</Mark1></Pgraph></Caption>
        </Table>
        <Table format="png">
          <MediaNo>3</MediaNo>
          <MediaID language="en">3en</MediaID>
          <MediaID language="de">3de</MediaID>
          <Caption language="en"><Pgraph><Mark1>Table 3: Results objective resuscitation quality</Mark1></Pgraph></Caption>
          <Caption language="de"><Pgraph><Mark1>Tabelle 3: Ergebnisse objektive Reanimationsqualit&#228;t</Mark1></Pgraph></Caption>
        </Table>
        <Table format="png">
          <MediaNo>4</MediaNo>
          <MediaID language="en">4en</MediaID>
          <MediaID language="de">4de</MediaID>
          <Caption language="en"><Pgraph><Mark1>Table 4: Lay resuscitation checklist</Mark1></Pgraph></Caption>
          <Caption language="de"><Pgraph><Mark1>Tabelle 4: Checkliste Laienreanimation</Mark1></Pgraph></Caption>
        </Table>
        <Table format="png">
          <MediaNo>5</MediaNo>
          <MediaID language="en">5en</MediaID>
          <MediaID language="de">5de</MediaID>
          <Caption language="en"><Pgraph><Mark1>Table 5: Standardized responses to subjects&#8217; questions</Mark1></Pgraph></Caption>
          <Caption language="de"><Pgraph><Mark1>Tabelle 5: Standardisierte Antworten auf R&#252;ckfragen der Versuchsperson</Mark1></Pgraph></Caption>
        </Table>
        <Table format="png">
          <MediaNo>6</MediaNo>
          <MediaID language="en">6en</MediaID>
          <MediaID language="de">6de</MediaID>
          <Caption language="en"><Pgraph><Mark1>Table 6: Sample description SIMARENA trial</Mark1></Pgraph></Caption>
          <Caption language="de"><Pgraph><Mark1>Tabelle 6: Stichprobenbeschreibung SIMARENA-Studie</Mark1></Pgraph></Caption>
        </Table>
        <Table format="png">
          <MediaNo>7</MediaNo>
          <MediaID language="en">7en</MediaID>
          <MediaID language="de">7de</MediaID>
          <Caption language="en"><Pgraph><Mark1>Table 7: Results subjective stress perception</Mark1></Pgraph></Caption>
          <Caption language="de"><Pgraph><Mark1>Tabelle 7: Ergebnisse subjektives Stressempfinden</Mark1></Pgraph></Caption>
        </Table>
        <Table format="png">
          <MediaNo>8</MediaNo>
          <MediaID language="en">8en</MediaID>
          <MediaID language="de">8de</MediaID>
          <Caption language="en"><Pgraph><Mark1>Table 8: Results objective stress perception</Mark1></Pgraph></Caption>
          <Caption language="de"><Pgraph><Mark1>Tabelle 8: Ergebnisse objektives Stressempfinden</Mark1></Pgraph></Caption>
        </Table>
        <Table format="png">
          <MediaNo>9</MediaNo>
          <MediaID language="en">9en</MediaID>
          <MediaID language="de">9de</MediaID>
          <Caption language="en"><Pgraph><Mark1>Table 9: Results subjective resuscitation quality</Mark1></Pgraph></Caption>
          <Caption language="de"><Pgraph><Mark1>Tabelle 9: Ergebnisse subjektive Reanimationsqualit&#228;t</Mark1></Pgraph></Caption>
        </Table>
        <NoOfTables>9</NoOfTables>
      </Tables>
      <Figures>
        <Figure width="1115" height="705" format="png">
          <MediaNo>1</MediaNo>
          <MediaID>1</MediaID>
          <Caption language="en"><Pgraph><Mark1>Figure 1: SAM floor plan (&#169;Leschowski)</Mark1></Pgraph></Caption>
          <Caption language="de"><Pgraph><Mark1>Abbildung 1: Grundriss der SAM (&#169;Leschowski)</Mark1></Pgraph></Caption>
        </Figure>
        <Figure width="1200" height="448" format="png">
          <MediaNo>2</MediaNo>
          <MediaID>2</MediaID>
          <Caption language="en"><Pgraph><Mark1>Figure 2: 3D Model: (A) overview and (B) interior view of the SAM (&#169;Leschowski)</Mark1></Pgraph></Caption>
          <Caption language="de"><Pgraph><Mark1>Abbildung 2: 3D-Modell: (A) &#220;bersicht und (B) Innenansicht der SAM (&#169;Leschowski)</Mark1></Pgraph></Caption>
        </Figure>
        <Figure width="554" height="369" format="png">
          <MediaNo>3</MediaNo>
          <MediaID>3</MediaID>
          <Caption language="en"><Pgraph><Mark1>Figure 3: Forest scenario in SAM (&#169;Leschowski)</Mark1></Pgraph></Caption>
          <Caption language="de"><Pgraph><Mark1>Abbildung 3: Wald-Szenario in der SAM (&#169;Leschowski)</Mark1></Pgraph></Caption>
        </Figure>
        <Figure width="887" height="278" format="png">
          <MediaNo>4</MediaNo>
          <MediaID language="en">4en</MediaID>
          <MediaID language="de">4de</MediaID>
          <Caption language="en"><Pgraph><Mark1>Figure 4: SIMARENA trial schedule (&#169;Leschowski)</Mark1></Pgraph></Caption>
          <Caption language="de"><Pgraph><Mark1>Abbildung 4: Ablaufplan der SIMARENA-Studie (&#169;Leschowski)</Mark1></Pgraph></Caption>
        </Figure>
        <Figure width="554" height="416" format="png">
          <MediaNo>5</MediaNo>
          <MediaID>5</MediaID>
          <Caption language="en"><Pgraph><Mark1>Figure 5: Control group simulation environment (&#169;Leschowski)</Mark1></Pgraph></Caption>
          <Caption language="de"><Pgraph><Mark1>Abbildung 5: Simulationsumgebung der Kontrollgruppe in der SAM (&#169;Leschowski)</Mark1></Pgraph></Caption>
        </Figure>
        <Figure width="554" height="416" format="png">
          <MediaNo>6</MediaNo>
          <MediaID>6</MediaID>
          <Caption language="en"><Pgraph><Mark1>Figure 6: Intervention group simulation environment (&#169;Leschowski)</Mark1></Pgraph></Caption>
          <Caption language="de"><Pgraph><Mark1>Abbildung 6: Simulationsumgebung der Interventionsgruppe in der SAM (&#169;Leschowski)</Mark1></Pgraph></Caption>
        </Figure>
        <Figure width="595" height="329" format="png">
          <MediaNo>7</MediaNo>
          <MediaID language="en">7en</MediaID>
          <MediaID language="de">7de</MediaID>
          <Caption language="en"><Pgraph><Mark1>Figure 7: VAS-S over time (blue: IG, grey: CG)</Mark1></Pgraph></Caption>
          <Caption language="de"><Pgraph><Mark1>Abbildung 7: VAS-S im Zeitverlauf (blau: IG; grau: KG)</Mark1></Pgraph></Caption>
        </Figure>
        <Figure width="626" height="329" format="png">
          <MediaNo>8</MediaNo>
          <MediaID language="en">8en</MediaID>
          <MediaID language="de">8de</MediaID>
          <Caption language="en"><Pgraph><Mark1>Figure 8: Cardiac reactivity (blue: IG, grey: CG)</Mark1></Pgraph></Caption>
          <Caption language="de"><Pgraph><Mark1>Abbildung 8: Kardiale Reaktivit&#228;t (blau: IG; grau: KG)</Mark1></Pgraph></Caption>
        </Figure>
        <Figure width="570" height="333" format="png">
          <MediaNo>9</MediaNo>
          <MediaID language="en">9en</MediaID>
          <MediaID language="de">9de</MediaID>
          <Caption language="en"><Pgraph><Mark1>Figure 9: Error frequencies according to checklist (blue: IG, grey: CG)</Mark1></Pgraph></Caption>
          <Caption language="de"><Pgraph><Mark1>Abbildung 9: Fehlerh&#228;ufigkeiten nach Checkliste (blau: IG; grau: KG)</Mark1></Pgraph></Caption>
        </Figure>
        <Figure width="554" height="294" format="png">
          <MediaNo>10</MediaNo>
          <MediaID language="en">10en</MediaID>
          <MediaID language="de">10de</MediaID>
          <Caption language="en"><Pgraph><Mark1>Figure 10: Influence of the SAM according to the Yerkes-Dodson theory</Mark1></Pgraph></Caption>
          <Caption language="de"><Pgraph><Mark1>Abbildung 10: Einfluss der SAM nach der Yerkes-Dodson-Theorie</Mark1></Pgraph></Caption>
        </Figure>
        <NoOfPictures>10</NoOfPictures>
      </Figures>
      <InlineFigures>
        <NoOfPictures>0</NoOfPictures>
      </InlineFigures>
      <Attachments>
        <NoOfAttachments>0</NoOfAttachments>
      </Attachments>
    </Media>
  </OrigData>
</GmsArticle>